| поискавой системы для электроныых деталей |
|
DP7419 датащи(PDF) 4 Page - Copal Electronics |
|
|
|||||||||||||||||||||||||||||
DP7419 датащи(HTML) 4 Page - Copal Electronics |
|
4 / 16 page ![]() DP7419 Doc. No. MD-2115 Rev. H 4 © NIDEC COPAL ELECTRONICS CORP. Characteristics subject to change without notice D.C. OPERATING CHARACTERISTICS Over recommended operating conditions unless otherwise stated. s t i n U x a M n i M s n o i t i d n o C t s e T r e t e m a r a P l o b m y S ICC Power Supply Current fSCL A m 1 z H k 0 0 4 = ISB Standby Current (VCC = 5.0V) VIN = GND or VCC; SDA Open 1 µA ILI Input Leakage Current VIN = GND to VCC 10 µA ILO Output Leakage Current VOUT = GND to VCC 10 µA VIL V 1 - e g a t l o V w o L t u p n I CC x 0.3 V VIH V e g a t l o V h g i H t u p n I CC x 0.7 VCC + 1.0 V VOL1 Output Low Voltage (VCC = 3.0V) IOL V 4 . 0 A m 3 = PIN CAPACITANCE (1) Applicable over recommended operating range from TA = 25?C, f = 1.0 MHz, VCC = +5.0V (unless otherwise noted). s n o i t i d n o C s t i n U x a M p y T n i M s n o i t i d n o C t s e T l o b m y S CI/O V F p 8 ) A D S ( e c n a t i c a p a C t u p t u O I/O =0V CIN Input Capacitance (A0, A1, A2, A3, SCL, WP ¯¯¯) 6pF VIN =0V A.C. CHARACTERISTICS Over recommended operating conditions unless otherwise stated. s t i n U x a M p y T n i M r e t e m a r a P l o b m y S fSCL Clock Frequency 400 kHz TI (1) Noise Suppression Time Constant at SCL, SDA Inputs 50 ns tAA SLC Low to SDA Data Out and ACK Out 0.9 µs tBUF (1) Time the bus must be free before a new transmission can start 1.2 µs tHD:STA 6 . 0 e m i T d l o H n o i t i d n o C t r a t S µs tLOW 2 . 1 d o i r e P w o L k c o l C µs tHIGH 6 . 0 d o i r e P h g i H k c o l C µs tSU:STA Start Condition Setup Time (for a Repeated Start Condition) 0.6 µs tHD:DAT 0 e m i T d l o H n i a t a D ns tSU:DAT 0 0 1 e m i T p u t e S n i a t a D ns tR (1) SDA and SCL Rise Time 0.3 µs tF (1) SDA and SCL Fall Time 300 ns tSU:STO 6 . 0 e m i T p u t e S n o i t i d n o C p o t S µs tDH 0 5 e m i T d l o H t u O a t a D ns POWER UP TIMING (1) Over recommended operating conditions unless otherwise stated. s t i n U x a M p y T n i M r e t e m a r a P l o b m y S tPUR Power-up to Read Operation 1 ms tPUW Power-up to Write Operation 1 ms Note: (1) This parameter is tested initially and after a design or process change that affects the parameter. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |