14 / 24 page ![]() Data Sheet 14 Rev 1.0, 2012-10-01 TLE 8088 EM Power Drivers 6 Power Drivers 6.1 Low-Side Drivers The power stages are built by N-channel power MOSFET transistors. The channels are universal multi channel switches but mostly suitable to be used in Engine Management Systems. Within an Engine Management System, the best fit of the channels to the typical loads is: • Channel 1 for injector, valves or similar sized solenoids with a maximum operation current requirement of 2.6A • Channel 2 for malfunction indication lamps or other resistive loads with a maximum current requirement of 3A Figure 7 Low-side Switches Channel 1 has open load detection in off state. If an open load condition persists for a time longer than the filter time t d, an open load will be detected and the ST pin set to low. On the rising edge of the IN1 signal the ST pin will be released after the time t ST,clear , see Figure 9. In over-current situation channel 1 will be switched off and kept latched. Additionally the ST signal will be set to low after the settling time t ST,set,OC. On the falling edge of the IN1 signal the ST pin will be released after the time t ST,clear , see Figure 10. Therefore channel 1 can be switched on again by toggling the IN1 pin. During an over-temperature event the ST signal is set to low and will turn back to high if the failure condition is disappeared (see Table 1). In over-current situation the channel 2 will be switched off, and after typ. 4ms the channel will be switched on again. Channel 2 is also over-temperature protected. In over-temperature situation channel 2 will be switched off and will restart if the junction temperature falls by thermal shutdown hysteresis T OTH. Table 1 Truth Table for Diagnostics of CH1 Open Load Over Current Over Temperature ST Status 0 0 0 1 Normal operation 1 x x 0 Failure detected x 1 x 0 Failure detected and latched Channel 1 is switched off x x 1 0 Failure detected and channel 1 is switched off Failure Situation ST 0 = Situation doesn’t exist 1 = Normal operation 1 = Situation exists 0 = Failure detected X = 0 or 1 Vbat ID V DScl OUT V DS GND L, RL Vbat ID OUT V DS GND R Channel 1 Channel 2 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |