LF444 датащи(PDF) 7 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
LF444 датащи(HTML) 7 Page - National Semiconductor (TI) |
|
7 / 10 page ![]() Application Hints (Continued) Precautions should be taken to ensure that the power supply for the integrated circuit never becomes reversed in polarity or that the unit is not inadvertently installed backwards in a socket as an unlimited current surge through the resulting forward diode within the IC could cause fusing of the internal conductors and result in a destroyed unit. As with most amplifiers, care should be taken with lead dress, component placement and supply decoupling in order to ensure stability. For example, resistors from the output to an input should be placed with the body close to the input to minimize “pick-up” and maximize the frequency of the feed- back pole by minimizing the capacitance from the input to ground. A feedback pole is created when the feedback around any amplifier is resistive. The parallel resistance and capacitance from the input of the device (usually the inverting input) to AC ground set the frequency of the pole. In many instances the frequency of this pole is much greater than the expected 3 dB frequency of the closed loop gain and consequently there is negligible effect on stability margin. However, if the feed- back pole is less than approximately 6 times the expected 3 dB frequency a lead capacitor should be placed from the out- put to the input of the op amp. The value of the added ca- pacitor should be such that the RC time constant of this ca- pacitor and the resistance it parallels is greater than or equal to the original feedback pole time constant. Typical Application pH Probe Amplifier/Temperature Compensator DS009156-10 ***For R2 = 50k, R4 = 330k ±1% For R2 = 100k, R4 = 75k ±1% For R2 = 200k, R4 = 56k ±1% **Polystyrene *Film resistor type RN60C To calibrate, insert probe in pH =7 solution. Set the “TEMPERATURE ADJUST” pot, R2, to correspond to the solution temperature: full clockwise for 0˚C, and proportionately for intermediate temperatures, using a turns-counting dial. Then set “CALIBRATE” pot so output reads 7V. Typical probe = Ingold Electrodes #465-35 www.national.com 7 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |