| поискавой системы для электроныых деталей |
|
CS5.241 датащи(PDF) 17 Page - Red Lion Controls. Inc |
|
|
|||||||||||||||||||||||||||||
CS5.241 датащи(HTML) 17 Page - Red Lion Controls. Inc |
|
17 / 20 page ![]() CS5.241, CS5.241-C1, CS5.241-S1 C–Series 24V, 5A, SINGLE PHASE INPUT Dec. 2006 / Rev. 1.3 DS-CS5.241-EN All parameters are specified at 24V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 17/20 25.4. OUTPUT CIRCUIT BREAKERS Standard miniature circuit breakers (MCBs) can be used for branch protection. Ensure that the MCB is rated for DC voltage, too. The following tests show which circuit breakers the power supply typically trips. Circuit breakers have huge tolerances in their tripping behavior. Therefore, these typical tests can only be used as a recommendation or for comparing two different power supplies. Furthermore, the loop impedance has a major influence on whether a breaker trips or not. Two tests were performed, representing typical situations: Test 1: Short circuit with S1 on the power supply end of the cable (loop impedance approx. 20mOhm) Fig. 25-3 Branch protectors, test circuit 1 Circuit Breaker Power Supply AC DC + - I Load + - S1 Parameters: Input voltage: 230Vac, load current: 0A The following circuit breaker tripped during the test: A- or Z- Characteristic:: equal or smaller 8A B- Characteristic: no tripping ≥ 6A no breaker available < 6A C- Characteristic: equal or smaller 4A Test 2: Short circuit with S1 on the load end (additional impedance included; represents longer load wire length). Fig. 25-4 Branch protectors, test circuit 2 R Circuit Breaker Power Supply AC DC + - I S1 Load + - Parameters: Input voltage: 230Vac, load current: 0A The following circuit breaker tripped during the test: A- or Z- Characteristic:: ≤ 6A and R= 180mOhm B- Characteristic: no tripping ≥ 6A no breaker available < 6A C- Characteristic: ≤ 3A and R= 270mOhm What does this resistance mean in wire length? 0.5mm 2 0.7mm 2 1.0mm 2 1.5mm 2 2.5mm 2 4.0mm 2 180mOhm 5.0m 7.0m 10m 15m 25m 40m 270mOhm 7.5m 10.5m 15m 23m 38m 60m Example: Which wire gauge must be used to trip a C-Characteristic circuit breaker with a rating of 3A? The load wire length is 21m. Answer: A 3A C-Characteristic circuit breaker requires a loop impedance of less than 270mOhm (test results). The wire length table shows that up to 23m wire with a cross section of 1.5mm 2 are below 270mOhm. A wire not smaller than 1.5mm 2 shall be used. 25.5. INDUCTIVE AND CAPACITIVE LOADS The unit is designed to supply any kind of load, including unlimited capacitive and inductive loads. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |