| поискавой системы для электроныых деталей |
|
ATS605LSG датащи(PDF) 11 Page - Allegro MicroSystems |
|
|
|||||||||||||||||||||||||||||
ATS605LSG датащи(HTML) 11 Page - Allegro MicroSystems |
|
11 / 17 page ![]() Dual Output Differential Speed and Direction Sensor IC ATS605LSG 11 Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com Start Mode Hysteresis This feature helps to ensure optimal self-calibration by reject- ing electrical noise and low-amplitude target vibration during initialization. This prevents AGC from calibrating the IC on such spurious signals. Calibration can be performed using the actual target features. A typical scenario is shown in Figure 8. The Start Mode Hyster- esis, POHYS, is a minimum level of the peak-to-peak amplitude of the internal analog electrical signal, VPROC, that must be exceeded before the ATS605 starts to compute switchpoints. Figure 8: Operation of Start Mode Hysteresis • At power-on (position 1), the ATS605 begins sampling VPROC. • At the point where the Start Mode Hysteresis, POHYS, is exceeded, the device establishes an initial switching threshold, by using the Continuous Update algorithm. If VPROC is falling through the limit on the low side (position 2), the switchpoint is BRP, and if VPROC is rising through the limit on the high side (position 4), it is BOP. After this point, Start Mode Hysteresis is no longer a consider- ation. Note that a valid VPROC value exceeding the Start Mode Hysteresis can be generated either by a legitimate target feature or by excessive vibration. • In either case, because the switchpoint is immediately passed as soon as it is established, the ATS605 enables switching: --If on the low side, at BRP (position 2) the output would switch from low to high. However, because output is already high, no output switching occurs. At the next switchpoint, where BOP is passed (position 3), the output switches from high to low. --If on the high side, at BOP (position 4) the output switches from high to low. As this example demonstrates, initial output switching occurs with the same polarity, regardless of whether the Start Mode Hysteresis is exceeded on the high side or on the low side |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |