4 / 14 page ![]() Receiver Switching Characteristics ( Figures 1, 2, 3) Parameter Conditions Min Typ Max Units 8922 8922A/23A T pLH CL = 30 pF 12 22.5 20 ns T pHL CL = 30 pF 12 22.5 20 ns |T pLH–T pHL|CL = 30 pF 0.5 5 3.5 ns Skew (Channel to Channel) CL = 30 pF 0.5 3.0 2.0 ns T pLZ CL = 15 pF S2 Open 15 ns T pHZ CL = 15 pF S1 Open 15 ns T pZL CL = 30 pF S2 Open 20 ns T pZH CL = 30 pF S1 Open 20 ns Driver Switching Characteristics Parameter Conditions Min Typ Max Units 8922 8922A/23A SINGLE ENDED CHARACTERISTICS ( Figures 4, 5, 6, 8) T pLH CL = 30 pF 12 15 15 ns T pHL CL = 30 pF 12 15 15 ns T TLH CL = 30 pF 5 10 10 ns T THL CL = 30 pF 5 10 10 ns |T pLH–T pHL|CL = 30 pF 0.5 ns Skew CL = 30 pF (Note 5) 0.5 5 3.5 ns Skew (Channel to Channel) 0.5 3.0 2.0 ns T pLZ CL = 30 pF 15 ns T pHZ CL = 30 pF 15 ns T pZL CL = 30 pF 20 ns T pZH CL = 30 pF 20 ns DIFFERENTIAL SWITCHING CHARACTERISTICS (Note 6), ( Figure 4) T pLH CL = 30 pF 12 15 15 ns T pHL CL = 30 pF 12 15 15 ns |T pLH–T pHL|CL = 30 pF 0.5 6.0 2.75 ns Note 1: “Absolute Maximum Ratings” are those values beyond which the safety of the device cannot be guaranteed. They are not meant to imply that the device should be operated at these limits. The Table of “Electrical Characteristics” provides conditions for actual device operation. Note 2: All currents into device pins are shown as positive values; all currents out of the device are shown as negative; all voltages are referenced to ground unless otherwise specified. All values shown as max or min are classified on absolute value basis. Note 3: All typical values are VCC = 5V, TA = 25˚C. Note 4: Only one output at a time should be shorted. Note 5: Difference between complementary outputs at the 50% point. Note 6: Differential Delays are defined as calculated results from single ended rise and fall time measurements. This approach in establishing AC performance specifications has been taken due to limitations of available Automatic Test Equipment (ATE). The calculated ATE results assume a linear transition between measurement points and are a result of the following equations: Where: Tcp = Crossing Point Tra, Trb, Tfa and Tfb are time measurements with respect to the input. www.national.com 4 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |