| поискавой системы для электроныых деталей |
|
ISO7310C датащи(PDF) 13 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
ISO7310C датащи(HTML) 13 Page - Texas Instruments |
|
13 / 28 page ![]() ISO7310C, ISO7310FC www.ti.com SLLSEI8D – JUNE 2014 – REVISED APRIL 2015 8.3.1.2 Insulation Characteristics over recommended operating conditions (unless otherwise noted) PARAMETER(1) TEST CONDITIONS SPECIFICATION UNIT VIOWM Maximum isolation working voltage 400 VRMS Maximum repetitive peak voltage per VIORM 566 VPK DIN V VDE V 0884-10 After Input/Output safety test subgroup 2/3, VPR = VIORM x 1.2, t = 10 s, 680 Partial discharge < 5 pC Method a, After environmental tests subgroup 1, Input-to-output test voltage per VPR VPR = VIORM x 1.6, t = 10 s, 906 VPK DIN V VDE V 0884-10 Partial Discharge < 5 pC Method b1, VPR = VIORM x 1.875, t = 1 s (100% Production test) 1062 Partial discharge < 5 pC VTEST = VIOTM Maximum transient overvoltage per VIOTM t = 60 sec (qualification) 4242 VPK DIN V VDE V 0884-10 t= 1 sec (100% production) Maximum surge isolation voltage per Test method per IEC 60065, 1.2/50 µs waveform, VIOSM 6000 VPK DIN V VDE V 0884-10 VTEST = 1.3 x VIOSM = 7800 VPK (qualification) VTEST = VISO = 3000 VRMS, t = 60 sec (qualification); VISO Withstand isolation voltage per UL 1577 3000 VRMS VTEST = 1.2 x VISO = 3600 VRMS, t = 1 sec (100% production) RS Insulation resistance VIO = 500 V at TS = 150°C >109 Ω Pollution degree 2 (1) Climatic Classification 40/125/21 Table 1. IEC 60664-1 Ratings Table PARAMETER TEST CONDITIONS SPECIFICATION Basic isolation group Material group II Rated mains voltage ≤ 150 VRMS I–IV Installation classification Rated mains voltage ≤ 300 VRMS I–III 8.3.1.3 Regulatory Information VDE CSA UL CQC Certified according to DIN V VDE Approved under CSA Recognized under UL 1577 V 0884-10 (VDE V 0884- Component Acceptance Notice Certified according to GB4943.1- Component Recognition 10):2006-12 and DIN EN 61010- 5A, IEC 60950-1, and IEC 2011 Program 1 (VDE 0411-1):2011-07 61010-1 400 VRMS Basic Insulation and 200 VRMS Reinforced Insulation Basic Insulation working voltage per CSA Maximum Transient Overvoltage, 60950-1-07+A1+A2 and IEC 4242 VPK; Basic Insulation, Altitude ≤ 5000 m, 60950-1 2nd Ed.+A1+A2; Maximum Surge Isolation Single protection, 3000 VRMS (1) Tropical Climate, 250 VRMS 300 VRMS Basic Insulation Voltage, 6000 VPK; maximum working voltage working voltage per CSA Maximum Repetitive Peak 61010-1-12 and IEC 61010-1 Voltage, 566 VPK 3rd Ed. Master contract number: Certificate number: Certificate number: 40016131 File number: E181974 220991 CQC15001121656 (1) Production tested ≥ 3600 VRMS for 1 second in accordance with UL 1577. Copyright © 2014–2015, Texas Instruments Incorporated Submit Documentation Feedback 13 Product Folder Links: ISO7310C ISO7310FC |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |