| поискавой системы для электроныых деталей |
|
PCM1608 датащи(PDF) 13 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
PCM1608 датащи(HTML) 13 Page - Texas Instruments |
|
13 / 29 page ![]() PCM1608 13 SBAS164A FIGURE 8. Read Operation Timing. 10 00 00 00 X X XX XXXX X XX X X X X X XX X X XX X X High Impedance ML MC MDI MDO ML MC MDI MDO ML MC MDI MDO D7 D0 D6 D5 D4 D3 D2 D1 D0 High Impedance D7 D6 D5 D4 INDEX “N – 1” D3 D2 D1 D6 D7 D5 D4 D3 D2 D1 D0 INDEX “1” INDEX “N” INC = 1 (Auto-Increment Read) 10 00 00 00 X XX XXXX X High Impedance D6 D7 D5 D4 D3 D2 D1 D0 INDEX “N” INC = 0 (Single Register Read) NOTES: (1) X = Don’t care. (2) Index which it begins to read in the read mode can set by REG[6:0] in Register 11, data from Register 1 to Register 12 can be read by setting it as “INC = 1” in Register 11. For example, set REG[6:0] = “0001001” to read from Register 9. (INC = “0” or “1”.) The details of the Read operation are shown in Figure 8. First, Control Register 11 must be written with the index of the register to be read back. Additionally, the INC bit must be set to logic “0” in order to disable the Auto-Increment Read function. The Read cycle is then initiated by setting ML to logic “0” and setting the R/W bit of the control data word to logic “1”, indicating a Read operation. MDO remains at a high-impedance state until the last eight bits of the 16-bit read cycle, which corresponds to the eight data bits of the register indexed by the REG[6:0] bits of Control Register 11. The Read cycle is completed when ML is set to “1”, immediately after the MC clock cycle for the least significant bit of indexed control register has completed. AUTO-INCREMENT READ OPERATION The Auto-Increment Read function allows for multiple regis- ters to be read sequentially. The Auto-Increment Read func- tion is enabled by setting the INC bit of Control Register 11 to “1”. The sequence always starts with Register 1, and ends with the register indexed by the REG[6:0] bits in Control Register 11. Figure 8 shows the timing of the Auto-Increment Read operation. The operation begins by writing Control Regis- ter 11, setting INC to “1”, and setting REG[6:0] to the last register to be read in the sequence. The actual Read opera- tion starts on the next HIGH to LOW transition of the ML pin. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |