14 / 50 page ![]() Zone 0 Zone 1 Zone 2 Zone 3 Zone 4 µ5¶= Rest, µ+¶= Increase, µ-µ= Decrease 0 1 1 3 4 4 0 4 + R + + + R R R Brightness Zone Zone 0 Zone 1 Zone 2 Zone 3 Zone 4 4 3 3 1 0 0 4 0 - R - - - R R R Brightness Zone Zone 0 Zone 1 Zone 2 Zone 3 Zone 4 0 4 4 4 4 1 0 1 + + - + - - R R Brightness Zone Averager Output Zone 0 Zone 1 Zone 2 Zone 3 Zone 4 1 3 4 2 2 1 1 Averager Output Zone Average 1.0 1.75 3.5 4.0 2.25 2.25 1.5 LM3530 SNVS606L – JUNE 2009 – REVISED DECEMBER 2014 www.ti.com Feature Description (continued) 2. The Averager will always round down to the lower zone in the event of a non-integer zone average. For example, if during an averaging period the ALS input transitions between zones 1 and 2 resulting in an averager output of 1.75, then the averager output will round down to 1 (see Figure 28). 3. The two most current averaging samples are used to make zone change decisions. 4. To make a zone change, data from three averaging cycles are needed. (Starting Value, First Transition, Second Transition or Rest). 5. To Increase the brightness zone, the Averager output must have increased for at least 2 averaging periods or increased and remained at the new level for at least two averaging periods ('+' to '+' or '+' to 'Rest' in Figure 29). 6. To decrease the brightness zone, the Averager output must have decreased for at least 2 averaging periods or decreased and remained at the new level for at least two averaging periods ('-' to '-' or '-' to 'Rest' in Figure 29). In the case of two consecutive increases or decreases in the Averager output, the LM3530 will transition to zone equal to the last averager output (Figure 29). Using the diagram for the ALS block (Figure 26), the flow of information is shown in (Figure 30). This starts with the ALS input into the A/D, into the Averager, and then into the Discriminator. Each state filters the previous output to help prevent unwanted zone to zone transitions. When using the ALS averaging function, it is important to remember that the averaging cycle is free running and is not synchronized with changing ambient lighting conditions. Due to the nature of the averager round down, an increase in brightness can take between 2 and 3 averaging cycles to change zones, while a decrease in brightness can take between 1 and 2 averaging cycles. See Table 6 for a list of possible Averager periods. Figure 31 shows an example of how the perceived brightness change time can vary. Figure 28. Averager Calculation Figure 29. Brightness Zone Change Examples 14 Submit Documentation Feedback Copyright © 2009–2014, Texas Instruments Incorporated Product Folder Links: LM3530 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |