7 / 11 page ![]() www.vishay.com 33 593D Vishay Sprague Document Number 40005 Revision 01-Mar-04 For technical questions, contact tantalum@vishay.com 7.1 At + 25 °C, the leakage current shall not exceed the value listed in the Standard Ratings Table. 7.2 At + 85 °C, the leakage current shall not exceed 10 times the value listed in the Standard Ratings Table. 7.3 At + 125 °C, the leakage current shall not exceed 12 times the value listed in the Standard Ratings Table. 8. ESR 8.1 ESR (Equivalent Series Resistance) shall not exceed the values listed in the Ratings Table. Measurement shall be made by the bridge method at a frequency of 100kHz and a temperature of +25°C. 9. Life Test: Capacitors shall withstand rated DC voltage applied at + 85°C or two-thirds rated voltage applied at + 125°C for 2000 hours. 9.1 Following the life test, the dissipation factor shall meet the initial requirement; the capacitance change shall not exceed ± 10%; the leakage current shall not exceed 125% of the initial requirement. 10. Vibration Tests: Capacitors shall be subjected to vibration tests in accordance with the following criteria. 10.1 Capacitors shall be secured for test by means of a rigid mounting using suitable brackets. 10.2 Low Frequency Vibration: Vibration shall consist of simple harmonic motion having an amplitude of 0.03" [0.76mm] and a maximum total excursion of 0.06" [1.52mm], in a direction perpendicular to the major axis of the capacitors. 10.2.1 Vibration frequency shall be varied uniformly between the approximate limits of 10 Hz to 55 Hz during a period of approximately one minute, continuously for 1.5 hours. 10.2.2 An oscilloscope or other comparable means shall be used in determining electrical intermittency during the final 30 minutes of the test. The AC voltage applied shall not exceed 2 volts rms. 10.2.3 Electrical tests shall show no evidence of intermittent contacts, open circuits or short circuits during these tests. 10.2.4 Following the low frequency vibration test, capacitors shall meet the original requirements for capacitance, dissipation factor and leakage current. 10.3 High Frequency Vibration: Vibration shall consist of PERFORMANCE CHARACTERISTICS (Continued) a simple harmonic motion having an amplitude of 0.06" [1.52] ± 10% maximum total excursion or 20 g peak whichever is less. 10.3.1 Vibration frequency shall be varied logarithmically from 50 Hz to 2000 Hz and return to 50 Hz during a cycle period of 20 minutes. 10.3.2 The vibration shall be applied for 4 hours in each of 2 directions, parallel and perpendicular to the major axis of the capacitors. 10.3.3 Rated DC voltage shall be applied during the vibration cycling. 10.3.4 An oscilloscope or other comparable means shall be used in determining electrical intermittency during the last cycle. The AC voltage applied shall not exceed 2 volts rms. 10.3.5 Electrical tests shall show no evidence of intermittent contacts, open circuits or short circuits during these tests. 10.3.6 There shall be no mechanical damage to these capacitors as a result of these tests. 10.3.7 Following the high frequency vibration test, capacitors shall meet the original limits for capacitance, dissipation factor and leakage current. 11. Acceleration Test: 11.1 Capacitors shall be rigidly mounted by means of suitable brackets. 11.2 Capacitors shall be subjected to a constant acceleration of 100 g for a period of 10 seconds in each of 2 mutually perpendicular planes. 11.2.1 The direction of motion shall be parallel to and per- pendicular to the longitudinal axis of the capacitors. 11.3 Rated DC voltage shall be applied during acceleration test. 11.3.1 An oscilloscope or other comparable means shall be used in determining electrical intermittency during test. The AC voltage applied shall not exceed 2 volts rms. 11.4 Electrical tests shall show no evidence of intermittent contacts, open circuits or short circuits during these tests. 11.5 There shall be no mechancial damage to these capacitors as a result of these tests. 11.6 Following the acceleration test, capacitors shall meet the original limits for capacitance, dissipation factor and leakage current. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |