30CPQ080 датащи(PDF) 2 Page - International Rectifier |
|
|
|||||||||||||||||||||||||||||
30CPQ080 датащи(HTML) 2 Page - International Rectifier |
|
2 / 4 page ![]() 30CPQ080, 30CPQ100 PD-2.333 rev. A 12/97 2 www.irf.com Part number 30CPQ080 30CPQ100 V R Max. DC Reverse Voltage (V) V RWM Max. Working Peak Reverse Voltage (V) 80 100 T J Max.JunctionTemperatureRange -55to175 °C T stg Max.StorageTemperatureRange -55to175 °C R thJC Max.ThermalResistanceJunction 2.20 °C/W DCoperation * See Fig. 4 toCase (Per Leg) R thJC Max.ThermalResistanceJunction 1.10 °C/W DCoperation toCase(Per Package) R thCS TypicalThermalResistance,Case 0.24 °C/W Mountingsurface,smoothandgreased toHeatsink wt ApproximateWeight 6(0.21) g(oz.) T MountingTorque Min. 6(5) Non-lubricatedthreads Max. 12(10) Case Style TO-247AC(TO-3P) JEDEC Thermal-Mechanical Specifications Kg-cm (Ibf-in) Parameters 30CPQ... Units Conditions Absolute Maximum Ratings Following any rated load condition and with rated V RRM applied Parameters 30CPQ... Units Conditions A V FM Max. Forward Voltage Drop 0.86 V @ 15A (Per Leg) * See Fig. 1 (1) 1.05 V @ 30A 0.67 V @ 15A 0.81 V @ 30A I RM Max. Reverse Leakage Current 0.55 mA T J = 25 °C (Per Leg) * See Fig. 2 (1) 7 mA T J = 125 °C C T Max. Junction Capacitance (Per Leg) 500 pF V R = 5V DC , (test signal range 100Khz to 1Mhz) 25°C L S Typical Series Inductance (Per Leg) 7.5 nH Measured lead to lead 5mm from package body dv/dt Max. Voltage Rate of Change 10,000 V/ µs (Rated V R ) T J = 25 °C T J = 125 °C V R = rated V R Parameters 30CPQ... Units Conditions (1) Pulse Width < 300µs, Duty Cycle <2% Voltage Ratings Electrical Specifications I F(AV) Max.AverageForwardCurrent 30 A 50%dutycycle@T C = 140°C,rectangularwaveform * See Fig. 5 I FSM Max.PeakOneCycleNon-Repetitive 920 5µs Sine or 3µs Rect. pulse SurgeCurrent (Per Leg) *SeeFig.7 240 10ms Sine or 6ms Rect. pulse E AS Non-RepetitiveAvalancheEnergy 7.50 mJ T J = 25 °C, I AS = 0.50 Amps, L = 60 mH (Per Leg) I AR RepetitiveAvalancheCurrent 0.50 A Currentdecayinglinearlytozeroin1µsec (Per Leg) Frequency limited by T J max. V A = 1.5 x V R typical |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |