14 / 16 page ![]() INTEGRATED CIRCUITS DIVISION 14 www.ixysic.com R01 CPC7691 of switching power diodes connected to FGND, one from TBAT and the other from RBAT, oriented to forward conduct whenever the potential at either TBAT or RBAT becomes positive with respect to FGND. For negative potential fault situations, the CPC7691BA utilizes a voltage fold-back SCR to direct fault currents to FGND, away from the external devices, while the CPC7691BB uses a pair of switching power diodes to direct the fault currents to VBAT. The SCR protection technique of the CPC7691BA uses the VBAT supply as a reference and as a current source for the SCR trigger to activate the SCR. During a negative transient event resulting in a bias at TBAT or RBAT of 2V to 4V more negative than VBAT, the SCR conducts and faults are shunted to FGND. In order for the SCR to crowbar (or foldback), the SCR’s on-voltage (see “Protection Circuitry Electrical Specifications” on page 8) must be less than the applied voltage at the VBAT pin. If the VBAT voltage is less negative than the SCR on-voltage, or if the VBAT supply is unable to source the trigger current, the SCR will not crowbar. Unlike the CPC7691BA which uses one-half of a diode bridge and an SCR for the internal protection, the CPC7691BB instead uses a full diode bridge to clamp both polarities of a transient fault. In the CPC7691BB a pair of power switching diodes are used to direct excessive negative potentials at the TBAT and RBAT nodes into VBAT. These diodes are oriented so that anytime the potentials at the TBAT or RBAT nodes become more negative than VBAT they forward conduct. Because these diodes direct negative potential faults to the VBAT pin, the battery supply must be capable of sourcing currents equal in magnitude to the total currents of all simultaneous faults. As mentioned earlier, the fault currents are restricted by the current limits of the break switches. Use of the CPC7691BA is recommended for applications where the local VBAT supply is incapable of sourcing the cumulative transient current demands of simultaneous multiple port faults. 2.10.3 Thermal Shutdown The thermal shutdown mechanism activates when the device die temperature reaches a minimum of 110 C, placing the device in the All-Off state regardless of logic input. During thermal shutdown events the TSD pin will output a logic low with a nominal 0V level. A logic high is output from the TSD pin during normal operation with a typical output level equal to VDD. When presented with short duration transients such as a lightning event, the thermal shutdown feature will typically not activate. But in an extended power-cross event, fault currents limited by the DC current limit function flowing through the active switches will cause the device temperature to rise until the thermal shutdown mechanism activates. Activation of the thermal shutdown mechanism forces the CPC7691 into the All-Off state. At this point the current measured into TLINE or RLINE will drop to zero. Once the device enters thermal shutdown it will remain in the All-Off state until the device temperature drops below the de-activation level of the thermal shutdown circuit. This permits the device to autonomously return to normal operation. If the fault condition has not passed, the limited current will again flow through the active switches and heating will resume, reactivating the thermal shutdown mechanism. This cycle of entering and exiting the thermal shutdown mode will continue as long as the fault condition persists. If the magnitude of the fault condition is great enough, the external secondary protector will activate shunting the fault current to ground. 2.11 External Protection Elements The CPC7691 requires only over-voltage secondary protection on the loop (line) side of the device. The integrated protection feature described above negates the need for additional external protection on the SLIC side. The secondary protector must limit voltage transients to levels that do not exceed the breakdown voltage or input-output isolation barrier of the CPC7691. A foldback or crowbar type protector is recommended to minimize stresses on the switches. Consult IXYS Integrated Circuits Division’s application note, AN-144, Impulse Noise Benefits of Line Card Access Switches for equations related to the specifications of external secondary protectors, fuse resistors and PTCs. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |