| поискавой системы для электроныых деталей |
|
CS5530 датащи(PDF) 223 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
CS5530 датащи(HTML) 223 Page - National Semiconductor (TI) |
|
223 / 241 page ![]() Revision 4.1 223 www.national.com Register Descriptions (Continued) Table 4-37. Signature/Length Block for 0x43 Byte Offset Value 0 Signature: Always 0x00000070 4 Length: The length of the entire buffer including the signature block in bytes. 8 Reserved: Set to 0 12 Reserved: Set to 0 Table4-38. I/O Blockfor 0x43 Byte Offset Description 0 BYTE: Operation Type: 1 = Read 2= Write 3 = Read/And/Or/Write 4 = Define index and data ports In addition, values may be OR’ed in to the upper two bits of this byte to indicate that special functions are desired: 0x80 = Do not perform this operation (convert to NO-OP). 0x40 = This is an index operation. 1 BYTE: Reserved set to 0 2 BYTE: I/O Length: Determines whether a BYTE, WORD or DWORD operation is performed. 1 = BYTE operation 2 = WORD operation 3 = DWORD operation If BYTE 0 is a 4, then this field is used to indicate the size of the index write. 3 BYTE: Reserved set to 0 4 DWORD: I/O Address: This is the address in the I/O space to be used. It is always a WORD value. If this is a define index/data port operation, this DWORD contains the I/O address of the index port. If this is an index operation, other than define, this DWORD contains the value to be written to the index port. 8 DWORD: I/O Data: The meaning depends on the operation type: Read = This is where the data read from the I/O port will be placed. Write = This is the data to write to the I/O port. Read/AND/OR/Write = This is the data that will be ANDed with the data read from the I/O port. Define index/data port - This DWORD contains the I/O address of the data port. 12 DWORD: OR Data: This field is only used in a Read/AND/OR/Write operation. It contains the data that will be OR’ed after the data read was AND’ed with the previous field. After the OR is done, the data will be re-written to the I/O port. Note: In all cases if the data called for is shorter than the field, the data will be stored or retrieved from the least significant portion of the DWORD. Table 4-39. Audio Soft SMI Emulation (0x60-0x63) Soft SMI AX SETUP_IDX SETUP_DATA 0x6000 0x60 BP register value 0x6001 0x61 BP register value 0x6002 0x62 BX register value 0x6003 0x63 BX register value Note: Arbitrary registers cannot be set in ASL code before issuing a soft SMI. These commands provide an I/O interface to allow AUDIO Soft SMIs to be emulated. Table 4-40. Audio Power Control (0x64) Data Value Action 0 Power codec off and mute output 1 Power codec off, do not mute (allows CD to play) 2 Power codec on and un-mute output 3 Power codec on only Note: This command allows control of power to the audio codec as well as control of amplifier muting. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |