| поискавой системы для электроныых деталей |
|
HAS400-P датащи(PDF) 1 Page - LEM |
|
|
|||||||||||||||||||||||||||||
HAS400-P датащи(HTML) 1 Page - LEM |
|
1 / 3 page ![]() Page 1/3 29October2012/version 6 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com I PN = 50 .. 600 A Features ● Hall effect measuring principle ● Galvanic isolation between primary and secondary circuit ● Low power consumption ● Extended measuring range (3 x I PN) ● Isolated plastic case made of polycarbonate PBT recognized according to UL 94-V0 ● Right angle pins for direct PCB mounting. Advantages ● Easy mounting ● Small size and space saving ● Only one design for wide current ratings range ● High immunity to external interference. Applications ● AC variable speed drives ● Static converters for DC motor drives ● Battery supplied applications ● Uninterruptible Power Supplies (UPS) ● Switched Mode Power Supplies (SMPS) ● Power supplies for welding applications. Application domain ● Industrial. Current Transducer HAS 50 .. 600-P For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit and the secondary circuit. Electrical data Type Primary nominal Primary current, RoHS since current rms measuring range date code I PN (A) I PM (A) HAS 50-P 50 ± 150 46065 HAS 100-P 100 ± 300 46062 HAS 200-P 200 ± 600 76273 HAS 300-P 300 ± 900 76273 HAS 400-P 400 ± 900 46131 HAS 500-P 500 ± 900 46216 HAS 600-P 600 ± 900 76273 V C Supply voltage (± 5 %) 1) ± 15 V I C Current consumption ± 15 mA R IS Isolation resistance @ 500 VDC > 1000 MΩ V OUT Output voltage (Analog) @ ± I PN, RL = 10 kΩ, TA = 25°C ± 4 V ± 40 mV R OUT Output internal resistance approx 100 Ω R L Load resistance 2) > 1 kΩ X Accuracy @ I PN, TA = 25°C (excluding offset) < ± 1 % Accuracy - Dynamic performance data ε L Linearity error 3) (0 .. ± I PN) < ± 1 % of I PN V OE Electrical offset voltage, T A = 25°C < ± 20 mV V OH Hysteresis offset voltage @ I P = 0, after an excursion of 1 x I PN < ± 20 mV TCV OE Temperature coefficient of VOE HAS 50-P < ± 2 mV/K HAS 100 .. 600-P < ± 1 mV/K TCV OUT Temperature coefficient of VOUT (% of reading) < ± 0.1 %/K t r Response time to 90 % of I PN step < 3 µs di/dt di/dt accurately followed > 50 A/µs BW Frequency bandwidth 4) (small signal, - 3 dB) DC .. 50 kHz T A Ambient operating temperature - 10 .. + 80 °C General data T S Ambient storage temperature - 25 .. + 85 °C m Mass 80 g Standard EN 50178:1997 Notes: 1) Operating at ± 12 V ≤ V C < ± 15 V will reduce the measuring range 2) If the customer uses 1 kΩ of the load resistor, the primary current has to be limited as the nominal. To measure the full defined measuring range, the load resistor should be at minimum 10 kΩ 3) Linearity data exclude the electrical offset 4) Please refer to derating curves in the technical file to avoid excessive core heating at high frequency. |
Аналогичный номер детали - HAS400-P |
|
Аналогичное описание - HAS400-P |
|
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |