| поискавой системы для электроныых деталей |
|
QPC6713 датащи(PDF) 12 Page - RF Micro Devices |
|
|
|||||||||||||||||||||||||||||
QPC6713 датащи(HTML) 12 Page - RF Micro Devices |
|
12 / 17 page ![]() Revision DS20160112 - 12 of 17 - Disclaimer: Subject to change without notice © 2015 RF Micro Devices, Inc. www.rfmd.com / www.qorvo.com QPC6713 RFMD + TriQuint = Qorvo Pin Names and Descriptions Jumpers Connector Signal Position U1 Connection Comment S1 P3 Logic Voltage 0 VDD (From P1) 1 VIO (From P4) S2 A0 0 GND External Address 1 U1_VDD S3 A1 0 GND External Address 1 U1_VDD S4 A2 0 GND External Address 1 U1_VDD Note: Default jumper settings are BOLD Evaluation Board Programming Using USB Interface Serial Addressable Mode All programming jumpers on the evaluation board are set to the default values indicated in the table. Refer to the Control Bit Generator (CBG) Software Reference Manual for detailed instructions on how to setup the software for use. Apply the supply voltag e to P1. Select ‘QPC6713’ from the RFMD parts list of the CBG user interface. Set the attenuation value using the CBG user interface. The attenuator is set to the desired state and measurement can be taken. Note that the external address bits must all be set to ‘0’ when using the USB interface as the CGB software does not have the capability to set the external address in the serial data stream at this time. Evaluation Board Programming Using External Bus Serial Addressable Mode The configuration allows the user to control the attenuator through the P4 connector using an external harness. Remove the USB interface board if it is currently installed on the evaluation board. Connect a user-supplied harness to the P4 connector. Note that the top row of P4 contains the serial bus signals and the bottom row is ground. Programming jumper S1 is set to ‘0’. External address jumpers S2 through S4 can be set to any value desired by the user. Apply the supply voltage P1. Send the appropriate signals onto the serial bus lines in accordance with the Serial Mode Timing Diagram. The attenuator is set to the desired state and measurements can be taken. Default Power-up State The default attenuation state is maximum (31.75dB) when supply voltage is applied to the attenuator. The LE signal must be held to logic ‘0’ during power up. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |