| поискавой системы для электроныых деталей |
|
APR-B10 датащи(PDF) 1 Page - LEM |
|
|
|||||||||||||||||||||||||||||
APR-B10 датащи(HTML) 1 Page - LEM |
|
1 / 2 page ![]() Electrical data Primary Nominal Current Analogue Output Signal Type I PN (A.t.RMS) V OUT (V) 10,25,50 0-5V or 0-10V APR 50 B10 50,75,100 0-5V or 0-10V APR 100 B10 100,150,200 0-5V or 0-10V APR 200 B10 200,300,400 0-5V or 0-10V APR 400 B10 R L Load resistance ≥ 10 k Ω V C Supply voltage +24 ±5% V DC V d R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn 5 kV Limitation of voltage output 18 V Accuracy-Dynamic performance data X Accuracy @ I PN, TA = 25°C (without offset) < ±1 % of I PN εε L Linearity (0 .. ± I PN) < ±0.5 % of I PN V OE Electrical offset voltage, T A = 25°C < ±0.5 % of I PN V OT Thermal drift of V OE ±1 mV/K TC εε G Thermal drift of the gain (% of reading) ±0.1 %/K t r Response time @ 90% of I P < 1000 ms f Frequency bandwidth (-3 dB) 10 .. 6000 Hz General data T A Ambient operating temperature -20 .. +60 °C T S Ambient storage temperature -20 .. +85 °C m Mass 90 g Protection type IP20 Reliable isolation according to EN50178, EN61010 300 V AC Creepage distance > 5.5 mm EMC in accordance with EN50082-2 Plastic according to UL94V0, CTI 1 Notes : Installation and maintenance should be done with power supply disconnected. AC Current transducer APR-B10 Split core transducer for the electronic measurement distorted AC waveforms current, with galvanic isolation between the primary (High power) and the secondary circuits (Electronic circuit). Switch selectable ranges and True RMS 0-5V and 0-10V switch selectable voltage output. I PN = 10 .. 400 A 030708/0 Features • VFD and SCR waveforms current measurement • True RMS output • Split core type • 5V & 10V switch selectable voltage output. • DIN mounting & Panel mounting • Eliminates insertion loss • Switch selectable ranges Advantages • Large aperture for cable up to Ø18mm • High isolation between primary and secondary circuits • Easy to mount Applications • VFD Controlled Loads: VFD output indicates how the motor and attached load are operating. • SCR Controlled Loads: Acurate measurement of phase angle fired or burst fired (time proportioned) SCRs. Current measurement gives faster response than temperature measurement. • Switching Power Supplies and Electronic Ballasts: True RMS sensing is the most accurate way to measure power supply or ballast input power. LEM Components www.lem.com Preliminary |
Аналогичный номер детали - APR-B10 |
|
Аналогичное описание - APR-B10 |
|
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |