34 / 47 page ![]() Page 34 ams Datasheet Document Feedback [v1-01] 2016-Apr-11 AS5170 − Application Information 17. Read reg(0x000A) to reg (0x001E) ---> Read register step 3 18. Comparison of AS5170A/B Settings_Prog_final with content of read register step 3 19. If point 18 is correct, start the OTP burn procedure by writing: Reg(0x0062)=0x70 and Reg(0x0063)=0x51 20. Programming procedure is complete after 10ms 21. Clear the memory content writing 0x00 into reg (0x001E) 22. Write Reg0x23=0x40 to set the threshold for the guard band test (1) 23. 5ms wait time to refresh the non-volatile memory content with the OTP content 24. Read reg(0x000A) to reg (0x001E) ---> Read register step 4 25. If content from reg (0x001E) compares with content from “Signature Byte” refresh was successful 26. Comparison of AS5170A/B Settings_Prog_final with content of read register step 4. Mandatory: guard band test (1). 27. If point 26 fails, the test with the guard band (1) was not successful and the device is incorrectly programmed. A reprogramming is not allowed. 28. Clear the memory content writing 0x00 into reg (0x001E) 29. Write Reg0x23=0x00to set the threshold for the guard band test (1) 30. 5ms wait time to refresh the non-volatile memory content with the OTP content 31. Read reg(0x000A) to reg (0x001E) ---> Read register step 5 32. If content from reg (0x001E) compares with content from “Signature Byte” refresh was successful 33. Comparison of AS5170A/B Settings_Prog_final with content of read register step 5. Mandatory: guard band test (1) 34. If point 33 fails, the test with the guard band (1) was not successful and the device is incorrectly programmed. A reprogramming is not allowed. 35. Reset of the device. After power on the Sensor starts in functional mode Note(s): 1. Guard band test: Restricted to temperature range: 25 °C ± 20 °C Right after the programming procedure (max. 1 hour with same Conditions 25°C ± 20 °C) Same VDD voltage The guard band test is only for the verification of the burned OTP fuses during the programming sequence. A use of the guard band in other cases is not allowed. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |