| поискавой системы для электроныых деталей |
|
VEL05 датащи(PDF) 2 Page - XP Power Limited |
|
|
|||||||||||||||||||||||||||||
VEL05 датащи(HTML) 2 Page - XP Power Limited |
|
2 / 7 page ![]() VEL05 Series www.xppower.com 2 AC-DC Power Supplies Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 5.0 12.0 V See Models and Ratings table Minimum Load 0A No minimum load required Start Up Delay 4s Start Up Rise Time 50 ms Hold Up Time 8 ms Full load and 100 VAC Total Regulation 5% See Models and Ratings table Transient Response 4 % deviation Recovely within <1% within 500 µs for a 50% step load change at 0.2 A/µs Ripple & Noise 200 mV pk-pk 20 MHz bandwidth Short Circuit Protection Continuous, trip and restart (hiccup mode) with auto recovely Temperature Coefficient 0.05 %/ ˚C General Characteristic Minimum Typical Maximum Units Notes & Conditions Efficiency 74 79 % See Models and Ratings table Energy Efficiency Level VI Isolation 3000 VAC Input to Output Switching Frequency 24 70 kHz Variable Mean Time Between Failure 100 kHrs MIL-HDBK-217F at 25 °C GB Weight 0.28 (80) lb (g) Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Operating Temperature 0 +60 °C Derate from 100% load at 50 °C to 50% load at 60 °C Storage Temperature -40 +85 °C Operating Humidity 5 95 % RH, non-condensing Cooling Natural convection Shock 1 m drop onto concrete on each of 6 axes Vibration 10 300 Hz 2 g 15 mins/sweep, 30 mins for each of 3 axes EMC: Immunity Phenomenon Standard Test Level Criteria Notes & Conditions ESD Immunity EN61000-4-2 2,3 B ±4 kV contact, ±8 kV air Radiated Immunity EN61000-4-3 3 V/m A EFT/Burst EN61000-4-4 Level 2 B Surges EN61000-4-5 Level 2 A Conducted Immunity EN61000-4-6 3 V A Magnetic Fields EN61000-4-8 1 A/m A Dips and Interruptions EN55024 100% 10 ms, 30% 500 ms, 100% 5000 ms, Perf Criteria A, A, B EMC: Emissions Phenomenon Standard Test Level Notes & Conditions Conducted EN55022 Level B Radiated EN55022 Level B Harmonics Current EN61000-3-2 Class A Voltage Flicker EN61000-3-3 Safety Approvals Phenomenon Standard CB Report IEC60950-1 UL UL/cUL60950-1, approved as limited power source (LPS) TUV IEC60950-1 CCC |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |