| поискавой системы для электроныых деталей |
|
L9959 датащи(PDF) 29 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9959 датащи(HTML) 29 Page - STMicroelectronics |
|
29 / 49 page ![]() DocID027540 Rev 2 29/49 L9959 Application information 48 4.2.6 Open load (OL) Open load can either be detected in active mode or while the output drivers are in a tri-state condition, disabled by DIS or /ABE. Open load in active mode is enabled by setting the OLDA in the configuration register (CONFIG_REG). Open load in active mode With OLDA = '1', the open load condition can only be diagnosed if an inductive load is used. In normal operation, the output free wheels via the built-in diodes below ground, if the high- side output driver is switched-off. If the output does not go below ground, an open load is detected. It is possible to enable the filter OLDAFILTER by setting the dedicated bit 4 in SPECIAL_REG (0 or 40ms). With OLDAFILTER = '1', the open-load will be recheck at the next PWM cycle and if detected again, the failure will be confirmed in DIAG_REG1 (and latched). In case OLDAFILTER is set at '0' (40ms) the recheck will be executed after the filter time expiration and next PWM pulse. If detected again, the failure will be confirmed (and latched). Note: For Open-load in active mode L9959 works properly in case the duration of the transient conditions is less than 40msec (Transient condition: function of starting current, ending current, load electrical parameters, DC MOTOR mechanical characteristics...). Open load in inactive mode In inactive mode the open load is independent from the OLDAFILTER status (don't care condition) and it is detected by applying a pull-down current (IPD) to both outputs. A pull-up current is generated at one output to compensate these two output currents. If the pull-up current is in the range of one pull-down current, an open load is diagnosed. If the load is connected, the pull up current is in the range of the sum of both pull-down currents. An open load is detected, if the load resistance is above the open load resistance threshold; no open load is detected, if it is below this threshold (ROL). After the outputs are disabled, it takes the time tDIAGOL until the open load diagnostic can be enabled. The open load settling time to reach the correct pull up current is tdiagOL1, the open load filter time is tdiagOL2. 4.3 VS-undervoltage VS is monitored for under-voltage. If VS goes below the VS-undervoltage threshold, the outputs are switched to tristate after the time tFUV. 4.4 Inverse current at VS An inverse current of maximum 5 A, which decreases during a period of max 250 ms out of the device at VS does not lead to any destruction. After the exposure to such an inverse current the device returns to the specified functionality. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |