19 / 39 page ![]() AS3649 Datasheet - Detailed Descr i p ti on www.ams.com/AS3649 1.0-2 19 - 39 8.7 ADC The internal ADC is used to monitor LED temperature and DIE temperature. To operate the ADC, set the adc_channel (see page 27) and start the conversion by adc_convert. When adc_convert returns to ‘0’ the result is available in register adc_result (see page 30) (Bits 9...7)and adc_result_lsbs (Bits 1...0). The DIE junction temperature measurement returns the value according to Table 6: 8.8 I2C Serial Data Bus The AS3649 supports the I 2C bus protocol. A device that sends data onto the bus is defined as a transmitter and a device receiving data as a receiver. The device that controls the message is called a master. The devices that are controlled by the master are referred to as slaves. A master device that generates the serial clock (SCL), controls the bus access, and generates the START and STOP conditions must control the bus. The AS3649 operates as a slave on the I 2C bus. Within the bus specifications a standard mode (100kHz maximum clock rate) and a fast mode (400kHz maximum clock rate) are defined. The AS3649 works in both modes. Connections to the bus are made through the open-drain I/ O lines SDA and SCL. The following bus protocol has been defined (Figure 27): Data transfer may be initiated only when the bus is not busy. During data transfer, the data line must remain stable whenever the clock line is HIGH. Changes in the data line while the clock line is HIGH are interpreted as control signals. Accordingly, the following bus conditions have been defined: Bus Not Busy. Both data and clock lines remain HIGH. Start Data Transfer. A change in the state of the data line, from HIGH to LOW, while the clock is HIGH, defines a START condition. Stop Data Transfer. A change in the state of the data line, from LOW to HIGH, while the clock line is HIGH, defines the STOP condition. Table 6. Junction Temperature Measurement ADC result Junction Temperature - ºC ADC Return Value (10bit) -30 352 -20 343 -10 334 0 325 10 316 20 306 30 297 40 287 50 278 60 268 70 259 80 249 90 239 100 229 110 219 120 209 130 199 140 189 150 179 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |