| поискавой системы для электроныых деталей |
|
AXP209 датащи(PDF) 18 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
AXP209 датащи(HTML) 18 Page - List of Unclassifed Manufacturers |
|
18 / 45 page ![]() AXP209 Enhanced single Cell Li-Battery and Power System Management IC The Host can set IPS parameters and read the feedback by using internal registers in AXP209 via TWSI. Voltage Limiting/Current Limiting mode and Direct Mode In order not to affect the USB communication, VBUS is always working under Voltage-Limit mode by default. In this mode, AXP209 ensures that VBUS voltage remains above a configurable reference voltage VHOLD which can meet the USB specification. The default VHOLD is 4.4V, adjustable in Reg30H [5:3] register. If the system has limit on current obtained from USB VBUS, a current-limit mode is provided (See REG30H[1] register), with 900mA/500mA/100mA (Reg30H [0]) selectable. If the system just utilizes the USB for power supply rather than communication, or the USB power adapter is utilized, AXP209 can be set to “VBUS Direct Mode” by modifying register REG30H[6], and then AXP202 will give priority to the application power demand. When the drive ability of USB Host is insufficient or system power consumption is large then the VBUS voltage is lower than VHOLD, AXP202 will release IRQ to indicate the weak power supply ability of Host VBUS, which may affect USB communication, and then Host software will follow up. AXP209’s Reaction to External Power Supply Connection AXP209 can automatically detect the connection of external power and judge whether the power is usable or not. The result will be set in corresponding registers, and IRQ will be asserted to inform the Host at the same time. The following table has listed the status bits and meanings of external power registers: Status register bits Description Register REG00H [7] Indicates the presence of external ACIN Register REG00H [6] Indicates whether the external ACIN is usable or not Register REG00H [5] Indicates the presence of external VBUS Register REG00H [4] Indicates whether the external VBUS is usable or not Register REG00H [3] Indicates whether the VBUS voltage is above VHOLD when used Register REG00H [1] Indicates whether ACIN/VBUS short circuits on PCB or not Register REG00H [0] Indicates whether the system is triggered to startup by ACIN/VBUS The status bit indicating “whether the VBUS voltage is above VHOLD or not when used” allows the Host to judge when it receives IRQ7 (indicating weak supply ability) whether VBUS is pulled low by system load input or the external power itself is below VHOLD, which may facilitate Host software to decide either to keep on working in Voltage-Limit mode or switch to Direct Mode. When to Select VBUS as Input Power N_VBUSEN and register REG30H[7]: is used to determined when shall VBUS be used as the power supply N_VBUSEN REG30H [7] Input Power Description Low 0 VBUS Select if VBUS is valid and no ACIN is available Low 1 VBUS Select if VBUS is valid Confidential Page 18/45 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |