49 / 164 page ![]() Data Sheet 49 Rev. 1.1, 2014-09-26 TLE9263QX External Voltage Regulator 3 8.2 Functional Description The external voltage regulator can be used as an independent voltage regulator or in load-sharing mode with VCC1. Setting VCC3_ON in the M_S_CTRL register in SBC Normal Mode sets the stand-alone configuration of VCC3 as an independent voltage regulator. The load sharing configuration is set via the SPI bit VCC3_LS in the HW_CTRL register. Figure 18 Selecting the Configuration of the VCC3 Regulator Depending on the configuration the regulator will act in the respective SBC Mode as described in Table 12. After the VCC3 configuration has been selected, it cannot be changed anymore. In stand-alone configuration the maximum current ICC3max is defined by the current limitation determined by the used shunt. In load sharing configuration, the shunt is used to determine the current ratio between VCC1 and VCC3. Since the junction temperature of the external PNP transistor cannot be sensed by the SBC, it cannot be protected against over temperature by the SBC. Therefore the thermal behavior has to be analyzed by the application. For low-quiescent current reasons, the output voltage tolerance is decreased in SBC Stop Mode because a low- power mode regulator with a lower accuracy will be active for small loads. If the base current on VCC3 exceeds I VCC3base > IVCC3base,Ipeak,r then the high-power mode regulator is enabled additionally to support an optimum dynamic load behavior. If the base current on VCC3 falls below the threshold ( I VCC3base < IVCC3base,Ipeak,f), then the low-quiescent current consumption is resumed again by disabling the high-power mode regulator. Only the high-power mode regulator is active in SBC Normal Mode. The status of VCC3 is reported in the SUP_STAT_2 SPI register. The regulator will switch OFF in case of VS dropping below VS_UV regardless of the VCC3 configuration and will be automatically enabled again when exceeding this threshold voltage unless the control bit VCC3_VS_ UV_OFF is set. VCC3 will also stay active in SBC Stop Mode when the bit VCC3_LS_ STP_ON is set and when load sharing is configured (for detailed protection features see Chapter 15.7 and Chapter 16.3). Set bit VCC3_V_CFG = 0 Set bit VCC3_ON = 0 or 1 Set bit VCC3_LS = 1 VCC3_V_CFG is automatically set to 0 VCC3_LS, VCC3_ON and VCC3_V_CFG cannot be changed anymore VCC3_LS and VCC3_V_CFG cannot be changed anymore (once VCC3_ON is set for the first time) VCC3 load sharing? Default value of VCC3_LS = ‘0' VCC3 output voltage in stand-alone configuration Set bit VCC3_V_CFG = 1 Set bit VCC3_ON = 0 or 1 stand-alone configuration VCC3 = 5V stand-alone configuration VCC3 = 3.3V VCC3 load sharing VCC3 = VCC1 No Yes 5.0V 3.3V |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |