21 / 41 page ![]() Data Sheet 21 Rev. 1.4, 2014-10-28 TLE8209-2 Protection and Monitoring The short circuit to ground detection is activated when the current through one of the high side switches rises over the threshold IOUK and remains higher than IOUK for at least the filter time tDF_H within the blanking time tb. The output stage in which the short circuit was detected will be switched off within tDF_OFF. In H-bridge mode also the other output will be switched off after a short delay of tDF_del . In single switch mode only the affected output will be switched off. 8.5 Short Circuit to Battery A short circuit to battery is detected in the same way as a short circuit to ground, only in the low side switch instead of the high side switch. 8.6 Short Circuit across the Load Short circuit over load is indicated by two failures - short circuit to ground on one output and short circuit to battery on the other output. Both failure bits will be set in the SPI diagnostics register. Both output stages will be turned off. 8.7 Overtemperature In case of high DC-currents, insufficient cooling or high ambient temperature, the chip temperature may rise above the thermal shut-down temperature T SD (see Figure 11). In that case, all output transistors are turned off. 8.8 Undervoltage Shut-Down If the supply voltage at the VS pins falls below the undervoltage detection threshold VUV_OFF, the outputs switches are turned off. As soon as V S rises above VUV_ON again, the device is returning to normal operation. 8.9 Open Load Diagnosis Open load diagnosis is only possible if outputs are switched off by DIS or ABE. The diagnostic current sources are deactivated in status flag mode. Diagnostic current sources are disconnected if outputs are active. That means that the diagnostic current sources are also disconnected if the outputs are deactivated due to short circuit. The open load detection in H-bridge mode is different from the open load detection in single switch mode. Open Load Detection in H-Bridge mode Figure 13 Open Load Detection in H-Bridge Mode VDD + - Vref_L OUT1 OUT1_L + - Vref_L OUT2 OUT2_L |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |