9 / 51 page ![]() FOR AUTOMOTIVE 105°C OPERATION 2-WIRE REAL-TIME CLOCK Rev.2.2_00 S-35390A H Series Seiko Instruments Inc. 9 Configuration of Data Communication 1. Data communication For data communication, the master device in the system generates a start condition for the S-35390A H Series. Next, the master device transmits 4-bit device code "0110", 3-bit command and 1-bit read / write command to the SDA line. After that, output or input is performed from B7 of data. If data I/O has been completed, finish communication by inputting a stop condition to the S-35390A H Series. The master device generates an acknowledgment signal for every 1-byte. Regarding details, refer to " Serial Interface". Command 0 1 1 0 C2 C1 C0 R / W Device code ACK Read / write bit Acknowledgment bit B7 B6 B5 B4 B3 B2 B1 B0 ACK Start condition Stop condition 1-byte data STA STP Figure 9 Data Communication |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|