| поискавой системы для электроныых деталей |
|
MAX1106 датащи(PDF) 13 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX1106 датащи(HTML) 13 Page - Maxim Integrated Products |
|
13 / 16 page ![]() Single-Supply, Low-Power, Serial 8-Bit ADCs ______________________________________________________________________________________ 13 data out of this register at any time after the conversion is complete. After the eighth data-bit has clocked out, DOUT goes high impedance and remains so with addi- tional SCLKs. Normally leave CONVST low until a new conversion needs to be started. CONVST should be high for a maximum of 100µs to maintain the 8-bit accuracy of the Autozero Circuit. The acquisition time, tACQ, starts immediately after the end of conversion and a new conversion can be started immediately after all data has been clocked out by tog- gling CONVST high. Figure 8 shows a timing diagram for a conversion at the data rate of 40ksps. Typically 20µs are necessary for the conversion to complete, 4µs for reading the eight bits of data with a serial clock of 2MHz, and 1µs to complete the zero rail adjustment and acquisition. The conversion time is guaranteed to be less than 35µs, therefore the data rate should be limited to 25ksps unless the conversion time for the specific condition is known. Conversion time can be determined by measuring the time between CONVST falling edge and DOUT rising edge with a full-scale input voltage. __________Applications Information Power-On Reset When power is first applied with SHDN high or connect- ed to VDD, the MAX1106/MAX1107 is in track mode. Conversion can be started by toggling CONVST high to low as soon as the reference is settled when using the internal reference, or after 20µs when an external refer- ence is used. Powering up the MAX1106/MAX1107 with CONVST low will not start a conversion. No conversions should be performed until the reference voltage (inter- nal or external) has stabilized. Shutdown Operation Pulling SHDN low places the converter in low-current power-down mode. In this state the converter draws typically 0.5µA. In shutdown the analog biasing circuit and the internal bandgap reference are powered down, and DOUT goes high impedance. The conversion stops coincidentally with SHDN going low. If shutdown occurs during a conversion, power up, wait 35µs, and clock SCLK eight times. CONVST SCLK DOUT tCSPW tCONV tDV tCH #1 #8 tCL tDO tDV tTR tSCC Figure 7. Detailed Serial Interface Timing CONVST 5V/div SCLK 5V/div DOUT 5V/div 5 µs/div tCONV Figure 8. 40ksps Timing Diagram |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |