6 / 7 page ![]() Multilayer Ferrite Chip Inductor MERITEK CFB Series RoHS ENVIRONMENTAL CHARACTERISTICS Electrical Performance Test Item Requirement Test Method Inductance Refer to standard electrical characteristic spec. HP4291B Q HP4291B SRF HP4291B DC Resistance RDC Agilent 34401A Rated Current IDC Applied the current to coils, The inductance change should be less than 10% to initial value Mechanical Performance Test Item Requirement Test Method Resistance to Soldering Heat Appearance: No damage More than 75% of the terminal. Electrode should be covered with solder. Inductance: within ±15% of initial value Q: within ±30% of initial value Inductance: within±20% of initial value (0603 over 12uH) Pre-heating: 150°C, 1min. Solder Composition: Sn/Ag3.0/Cu0.5 (Pb-Free) Solder Temperature: 260±5°C (Pb-Free) Immersion Time: 10±1 sec. Solderability The electrodes shall be at least 90% covered with new solder coating Pre-heating: 150°C, 1min. Solder Composition: Sn/Ag3.0/Cu0.5 (Pb-Free) Solder Temperature: 245±5°C (Pb-Free) Immersion Time: 4±1 sec. Flexure Strength The forces applied on the right conditions must not damage the terminal electrode and the ferrite. Test device shall be soldered on the substrate Substrate Dimension: 100x40x1.6 mm Deflection: 2.0 mm Keeping Time: 30 sec. *For 0402, substrate dimension is 100x40x0.8 mm Vibration Test device shall be soldered on the substrate Oscillation Frequency: 10 to 55 to 10Hz for 1 min. Amplitude: 1.5 mm Time: 2 hrs for each axis (X, Y & Z), total 6 hrs Climatic Test Item Requirement Test Method Damp Heat with Load Appearance: No damage L change: within±10% of initial value Q change: within±30% of initial value Temperature: 40±2°C Relative Humidity: 90 ~ 95% Time: 1000 hrs Measured after exposure in the room condition for 24 hrs Temperature Cycle One cycle: Step Temperature (°C) Time (min.) 1 -25±3 30 2 25±2 3 3 85±3 30 4 25±2 3 Total: 100 cycles Measured after exposure in the room condition for 24 hrs High Temperature Resistance Temperature: 85±3°C Relative Humidity: 20% Applied Current: Rated Current Time: 1000 hrs Measured after exposure in the room condition for 24 hrs Low Temperature Resistance Temperature: -25±3°C Relative Humidity: 0% Time: 1000 hrs Measured after exposure in the room condition for 24 hrs |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |