| поискавой системы для электроныых деталей |
|
LTC1196 датащи(PDF) 17 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC1196 датащи(HTML) 17 Page - Linear Technology |
|
17 / 28 page ![]() 17 LTC1196/LTC1198 S APPLICATI I FOR ATIO Figure 4. LTC1198 Operation with DIN and DOUT Tied Together SAMPLE RATE (Hz) 0.01 0.1 1 10 100 10k 100k 1196/98 F05 0.001 1k 1M LT1196 VCC = 5V LT1196 VCC = 2.7V LT1198 VCC = 5V LT1198 VCC = 2.7V Figure 5. Supply Current vs Sample Rate for LTC1196/ LTC1198 Operating on 5V and 2.7V Supplies Minimize CS Low Time (LTC1198) In systems that have significant time between conver- sions, lowest power drain will occur with the minimum CS low time. Bringing CS low, transfering data as quickly as possible, then bringing it back high will result in the lowest current drain. This minimizes the amount of time the device draws power. OPERATING ON OTHER THAN 5V SUPPLIES The LTC1196/LTC1198 operate from single 2.7V to 6V supplies. To operate the LTC1196/LTC1198 on other than 5V supplies, a few things must be kept in mind. Input Logic Levels The input logic levels of CS, CLK and DIN are made to meet TTL on 5V supply. When the supply voltage varies, the input logic levels also change (see typical curve of Digital Input Logic Threshold vs Supply Voltage). For these two ADCs to sample and convert correctly, the digital inputs have to be in the logical low and high relative to the operating supply voltage. If achieving micropower consumption is desirable on the LTC1198, the digital inputs must go rail-to-rail between supply voltage and ground (see Reducing Power Consumption section). When the CS pin is high (= supply voltage), the LTC1198 is in shutdown mode and draws only leakage current. The status of the DIN and CLK input has no effect on the supply current during this time. There is no need to stop DIN and CLK with CS = high; they can continue to run without drawing current. 1 2 3 4 CLK DATA (DIN/DOUT) START SGL/DIFF ODD/SIGN DUMMY B7 B6 DUMMY BITS LATCHED BY LTC1198 LTC1198 CONTROLS DATA LINE AND SENDS A/D RESULT BACK TO THE DIGITAL SYSTEM THE DIGITAL SYSTEM CONTROLS DATA LINE AND SENDS MUX ADDRESS TO LTC1198 THE DIGITAL SYSTEM MUST RELEASE DATA LINE AFTER 5TH RISING CLK AND BEFORE THE 5TH FALLING CLK LTC1198 TAKES CONTROL OF DATA LINE ON 5TH FALLING CLK CS 1196/98 F04 5 DUMMY |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |