| поискавой системы для электроныых деталей |
|
AN4128 датащи(PDF) 18 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN4128 датащи(HTML) 18 Page - STMicroelectronics |
|
18 / 28 page ![]() Getting started AN4128 18/28 Doc ID 023306 Rev 1 Figure 24. Connection dongle1, dongle2 Now the two dongles are connected to one another and in -BypassMode-. In other words, everything typed on a terminal is transferred to the other via the Bluetooth link and vice versa. In -BypassMode- the dongle doesn't answer the commands. If, for example, the user needs to change some parameters of a dongle, it’s necessary to switch to -CommandMode-, giving the “escape command”. The escape command is a special sequence of characters followed by at least two seconds of inactivity on the serial port. The escape command sequence is: ^ #^$^%. Figure 25. Escape dongle1, dongle2 As can be noted, the escape command given to dongle1 doesn't affect dongle2 which remains in -BypassMode-. Connection between the two dongles is still active; to return to the “exchange data” situation, dongle1 must be reconfigured in -BypassMode- with the command “Bypass”. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |