Back Button PM0064 Datasheet HTML 5Page - STMicroelectronics PM0064 Datasheet HTML 6Page - STMicroelectronics PM0064 Datasheet HTML 7Page - STMicroelectronics PM0064 Datasheet HTML 8Page - STMicroelectronics PM0064 Datasheet HTML 9Page - STMicroelectronics PM0064 Datasheet HTML 10Page - STMicroelectronics PM0064 Datasheet HTML 11Page - STMicroelectronics PM0064 Datasheet HTML 12Page - STMicroelectronics PM0064 Datasheet HTML 13Page - STMicroelectronics  
Zoom Inzoom in Zoom Outzoom out
 9 / 13 page
background image
PM0064
Programming sequence
Doc ID 16274 Rev 3
9/13
Note:
The ‘Low’ level of Steps 6 and 7 during programming are not absolutely mandatory. They
could be ‘High’ if it is easier for the electronic command; provided they have the correct level
for the next state transition.
7.
CS = LOW
CS = 0 to prevent false signal when VREG is raised later on.
8.
VREG = VDD
Connect VREG to VDD (6.7 V).
9.
Wait 200 ms.
Allow time for option programming process.
10.
VREG release
Disconnect VREG from VDD.
11.
Wait 20 ms.
Allow time for VREG capacitor to discharge.
Table 5.
Option programming (State_4) (continued)
Step
Action
Explanation
Table 6.
Option programming (State_6)
Step
Action
Explanation
1.
CX - 1 double clock
Clock the IC into State_6.
2.
CS = HIGH
CS = 1 required to remain in State_6.
3.
CX - 1 double clock
Signal for IC to program options.
4.
CX = LOW
CX = 0 to prevent false signal when VREG is raised later on.
5.
CS = LOW
CS = 0 to prevent false signal when VREG is raised later on.
6.
VREG = VDD
Connect VREG to VDD (6.7 V).
7.
Wait 200ms
Allow time for option programming process.
8.
VREG release
VDD = 5.0 V
Disconnect VREG from VDD and decrease VDD voltage back to
5V.
9.
Wait 20 ms
Allow time for VREG capacitor to discharge.
10.
CX - 1 double clock
Clock the IC into State_7.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com