30 / 68 page ![]() ISO/IEC 14443-3 layers AN3955 30/68 Doc ID 022017 Rev 1 5.1.6 CR95HF configuration function The CR95HF configuration function sends a ProtocolSelect command to CR95HF device in order to select the ISO/IEC 14443-3 Type A protocol. The transmission and reception data rates are integrated in the command. This command turns on the RF field. Table 33 describes the ISO14443A_ProtocolSelect function. Table 33. ISO14443A_ProtocolSelect function description 5.1.7 ISO/IEC 14443-3 Type A command function These functions send a basic RF command to a contactless tag and check the CR95HF response. The ISO14443A_REQA function sends a REQA command to a contactless tag. Table 34 describes the ISO14443A_REQA function. Table 34. ISO14443A_REQA function description The ISO14443A_WUPA function sends a WUPA command to a contactless tag. Table 35 describes the ISO14443A_WUPA function. Table 35. ISO14443A_WUPA function description Prototype int8_t ISO14443A_ProtocolSelect (uc8TXDataRate, uc8 RxDataRate, uint8_t*pResponse); Input parameter TxDataRate: Transmission data rate (2 bits) RxDataRate: Reception data rate (2 bits) Output parameter pResponse: Pointer to the CR95HF response Return parameter RESULTOK: The ISO/IEC 14443-3 Type A protocol is selected. ISO14443A_ERRORCODE_PARAMETER: One parameter is incorrect. CR95HF_ERROR_CODE: Function failed. The ISO/IEC 14443-3 Type A protocol is not selected. Prototype ISO14443A_REQA (uint8_t *pResponse); Input parameter None Output parameter pResponse: Pointer to the CR95HF response Return parameter RESULTOK: The REQA command is successfully emitted to a contactless tag. CR95HF_ERROR_CODE: Function failed. The CR95HF returns an error code. Prototype int8_t ISO14443A_WUPA (uint8_t *pResponse); Input parameter None Output parameter pResponse: Pointer to the CR95HF response Return parameter RESULTOK: The WUPA command is successfully emitted to a contactless tag. CR95HF_ERROR_CODE: Function failed. The CR95HF returns an error code. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |