| поискавой системы для электроныых деталей |
|
AN3433 датащи(PDF) 8 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN3433 датащи(HTML) 8 Page - STMicroelectronics |
|
8 / 34 page ![]() Management of CR95HF or STRFNFCA activity AN3433 8/34 Doc ID 019046 Rev 2 Table 4. Idle command description Direction Data Comments Example Host to CR95HF or STRFNFCA 07 Command code Example of switch from Active mode to Hibernate state: >>>0x07 0E 08 04 00 04 00 18 00 00 00 00 00 00 00 00 Example of switch from Active to WFE mode (wakeup by low pulse on IRQ_IN pin): >>>0x07 0E 08 01 00 38 00 18 00 00 00 00 00 00 00 00 Example of switch from Active to WFE mode (wakeup by low pulse on SPI_SS pin): >>>0x07 0E 10 01 00 38 00 18 00 00 00 00 00 00 00 00 Example of wakeup by timeout (7 seconds): Duration before Timeout = 256 * tL * (WU period + 2) * (MaxSleep + 1) >>>0x07 0E 01 21 00 38 00 18 00 60 60 00 00 00 00 08 Example of switch from Active to Tag Detector mode (wakeup by tag detection or low pulse on IRQ_IN pin) (32 kHz, inactivity duration = 272 ms, DAC oscillator = 3 ms, Swing = 63 pulses of 13.56 MHz), 0A = Infinite sequence, 0B = Until TimeOut: >>>0x07 0E 0A 21 00 79 01 18 00 20 60 60 64 74 3F 08 Example of a basic Idle command used during the Tag Detection Calibration process: >>>0x07 0E 03 A1 00 F8 01 18 00 20 60 60 00 xx 3F 01 where xx is the DacDataH value. 0E Length of data <WU Source> Specifies authorized wakeup sources and the LFO frequency EnterCtrlL Settings to enter WFE mode EnterCtrlH WUCtrlL Settings to wake up from WFE mode WUCtrlH LeaveCtrlL Settings to leave WFE mode (Default value = 0x1800) LeaveCtrlH <WUPeriod> Period of time between two tag detection bursts. Also used to specify the duration before timeout. <OscStart> Defines the Wait time for HFO to stabilize: <OscStart> * tL (Default value = 0x60) <DacStart> Defines the Wait time for DAC to stabilize: <DacStart> * tL (Default value = 0x60) <DacDataL> Lower compare value for tag detection (1). This value must be set to 0x00 during Tag Detection Calibration. <DacDataH> Higher compare value for tag detection (1). This is a variable used during Tag Detection Calibration. <SwingsCnt> Number of swings HF during tag detection (Default value = 0x3F) <MaxSleep> Max. number of tag detection trials before timeout (1). This value must be set to 0x01 during Tag Detection Calibration. Also used to specify duration before timeout. MaxSleep must be: 0x00 < MaxSleep < 0x1F |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |