16 / 29 page ![]() Automatic confirmation of power-up AN3271 16/29 Doc ID 17933 Rev 2 8 Automatic confirmation of power-up Connect PSHOLD directly to the output voltage VOUT in order to enable automatic confirmation of power-up (see Figure 14). This allows immediate power-up but does not guarantee proper startup of the application. The enable signal EN (EN) is asserted immediately after pushing the PB button, thus enabling VOUT. Since PSHOLD is connected directly to VOUT, power-up is confirmed immediately and EN (EN) stays asserted. Please note that a small delay can be caused by capacitors connected between ground and VOUT elsewhere in the application. Figure 14. Automatic confirmation of power-up |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|