| поискавой системы для электроныых деталей |
|
AN3101 датащи(PDF) 17 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN3101 датащи(HTML) 17 Page - STMicroelectronics |
|
17 / 24 page ![]() DocID16612 Rev 6 17/24 AN3101 High speed internal oscillator calibration 23 2.3.4 HSI calibration demo description The demo provided with this application note shows the ability of the firmware to calibrate the HSI oscillator of the STM8L05xxx/15xxx, STM8L162xx and STM8AL31xx/3Lxx microcontrollers. By default, the demo is configured to run the calibration of the HSI oscillator routine using the LSE source frequency. To run the calibration process that provides the frequency with minimum error, you have to comment the following define line in the main.c file. Conversely, to run the calibration process that finds the frequency with a maximum allowed error, you have to uncomment the same line: /* #define USE_HSI_FIXED_ERROR */ To display the HSI signal, connect an oscilloscope probe to the PC4 pin and uncomment the following line in the main.c file: /* #define OUTPUT_HSI_ON_CCO_FOR_DEBUG */ 2.4 Recommendations on the use of the HSI calibration library 1. If the reference frequency used for HSI calibration is lower than 250 Hz, the TIM2 counter prescaler can be used to support low reference frequencies. 2. The TIM2 input capture divider (1, 2, 4 and 8) can be used to support high reference frequencies. 3. Frequency measurement accuracy is not guaranteed when using a reference frequency that exceeds 240 kHz. 4. It is not recommended to call calibration functions in an interrupt routine since, in this case, the calibration process may be long (refer to the Section 2.5.1). 5. It is recommended to stop all application activities before the calibration process, and to restart them after calling the calibration functions. The application therefore has to stop communications, ADC measurements (see Note: 1) etc. since these processes are supposed to use clock configurations different from those used in the calibration process. Otherwise, errors might be introduced in the application: errors while reading/sending frames, ADC reading errors since the sampling time has changed, etc. Note: 1 Except when using the ADC for the calibration process (refer to 7.). 6. The HSI calibration firmware uses the following peripherals: Clock (for trimming HSI), Timer 2 (for measuring HSI), Beeper (for connecting LSE to Timer 2 if LSE method is used). So, it is recommended to reconfigure these peripherals (if used in the application) after running HSI calibration routine 7. Real-time calibration vs. temperature can be used when the ambient temperature changes noticeably while the application is running. The internal temperature sensor can be used with the ADC watchdog with two thresholds. Each time an ADC watchdog interrupt occurs, a new HSI calibration process has to be performed and the two thresholds are updated according to the current temperature (this feature is not implemented in this application note): Threshold_High = CurrentTemperatureValue + TemperatureOffset Threshold_Low = CurrentTemperatureValue – TemperatureOffset |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |