33 / 53 page ![]() AN4070 STM32F103xx based current control for inverter grid connection Doc ID 022934 Rev 1 33/53 threshold of 440 V. In the case of bus DC under/overvoltage the system is disconnected from the grid according to the strategy already described. During normal operation the DC bus is regulated at 380 V. ● Burst mode operation at startup Burst mode operation is active during system startup and can also be activated for low load operation. During burst mode operation the DC bus voltage is regulated with hysteresis control. The boundary values of the hysteresis window Vb1, Vb2 are chosen to limit the DC bus voltage ripple to 2% of the reference value. Once the bus capacitor is charged, the control loop mode of operation is enabled and the connection to the grid performed. ● Line voltage and frequency detection and anti-islanding The PLL continuously measures the line voltage and frequency in all operating states. If the voltage or frequency exceeds the high or low limits, the inverter ceases to deliver power to the grid. These conditions are also used to implement a passive method for island operation detection. An island operation occurs when the utility power is disconnected for maintenance or fault reasons while the inverter is still delivering power. With a passive method, detection of islanding from the utility grid is achieved via AC under/overvoltage and under/over-frequency detection functions. ● Output overcurrent Due to fault conditions or AC line transient conditions, the maximum current may be exceeded. In this case, the inverter ceases to deliver power to the grid. The current threshold value is set to 1.2 A. The demonstration board is provided with the components required to implement hardware short-circuit protection. However, this protection is disabled and may be activated by properly sizing the R11 and R14 which currently have a zero Ohm value. ● Open loop operation This mode of operation has been implemented to allow system debug independently from grid operation. This mode, used for maintenance, test and debug, allows system operation only with manual control by acting on a set of pushbuttons on the board. The DC-DC converter power transfer can be adjusted by acting on the duty cycle parameter through the pushbutton placed on the microcontroller board. In the same way, the power transfer of the DC-AC converter can be modified acting on the modulating index. ● LCD display The microcontroller board is equipped with a graphic LCD display. The selectable functions are: 1. open loop mode; 2. closed loop mode; 3. calibration; 4. DC-DC converter manual control; 5. DC-AC converter manual control; 6. PI parameters manual regulation. It is important to note that the calibration function must be performed by the operator when the system is first connected to the grid. In this way, any offset affecting the feedback signals used for control mode operation is compensated via firmware. When the calibration function is executed the display shows a grid current offset of about 1.7 V and a grid voltage offset of about 2.2 V. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |