21 / 28 page ![]() Data Sheet ADuM1200/ADuM1201 Rev. I | Page 21 of 28 ABSOLUTE MAXIMUM RATINGS Ambient temperature = 25°C, unless otherwise noted. Table 13. Parameter Rating Storage Temperature (TST) −55°C to +150°C Ambient Operating Temperature (TA)1 −40°C to +105°C Ambient Operating Temperature (TA)2 −40°C to +125°C Supply Voltages (VDD1, VDD2)3 −0.5 V to +7.0 V Input Voltages (VIA, VIB)3, 4 −0.5 V to VDDI + 0.5 V Output Voltages (VOA, VOB)3, 4 −0.5 V to VDDO + 0.5 V Average Output Current per Pin (IO)5 −11 mA to +11 mA Common-Mode Transients (CML, CMH)6 −100 kV/μs to +100 kV/μs 1 Does not apply to ADuM1200W and ADuM1200W automotive grade products. 2 Applies to ADuM1200W and ADuM1201W automotive grade products. 3 All voltages are relative to their respective ground. 4 VDDI and VDDO refer to the supply voltages on the input and output sides of a given channel, respectively. 5 See for maximum rated current values for various temperatures. Figure 3 6 Refers to common-mode transients across the insulation barrier. Common-mode transients exceeding the absolute maximum ratings can cause latch-up or permanent damage. Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. ESD CAUTION Table 14. Maximum Continuous Working Voltage1 Parameter Max Unit Constraint AC Voltage, Bipolar Waveform 565 V peak 50-year minimum lifetime AC Voltage, Unipolar Waveform Functional Insulation 1131 V peak Maximum approved working voltage per IEC 60950-1 Basic Insulation 560 V peak Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10 DC Voltage Functional Insulation 1131 V peak Maximum approved working voltage per IEC 60950-1 Basic Insulation 560 V peak Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10 1 Refers to continuous voltage magnitude imposed across the isolation barrier. See the Insulation Lifetime section for more details. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |