| поискавой системы для электроныых деталей |
|
HIP9022AM датащи(PDF) 7 Page - Intersil Corporation |
|
|
|||||||||||||||||||||||||||||
HIP9022AM датащи(HTML) 7 Page - Intersil Corporation |
|
7 / 10 page ![]() 4-7 Address, Timing and Waveforms FIGURE 2. ADDRESS WITH SAMPLE, NULL, VIN AND DIAGONAL WAVEFORMS TABLE 1. HIP9022 ADDRESS MAP A3 A2 A1 A0 ADDRESS NO. FUNCTION TYPE FUNCTION NAME 0000 1 ANALOG VIN(DL) Voltage for Constant Current Level, Laser Driver #1 0001 2 ANALOG VIN(DL) Voltage for Constant Current Level, Laser Driver #2 0010 3 ANALOG VLOWER Level, Laser Driver #1 0011 4 ANALOG VLOWER Level, Laser Driver #2 0100 5 ANALOG VUPPER Level, Laser Driver #1 0101 6 ANALOG VUPPER Level, Laser Driver #2 0110 7 ANALOG VIN(DL) Thermal Compensation Level, Laser Driver #1 0111 8 ANALOG VIN(DL) Thermal Compensation Level, Laser Driver #2 1000 9 DIGITAL Test Mode: S/H Amp, Auto Zero Null Voltage (Note 4) 1001 10 DIGITAL Test Mode: S/H Amp Output Voltage (Note 4) 1010 11 DIGITAL Test Mode: Set VUP and VLOW Amps to Three-State (Note 4) 1011 12 DIGITAL VLOW#1 Set to Positive Output (Default is Negative) 1100 13 DIGITAL VLOW#2 Set to Positive Output (Default is Negative) 1101 14 DIGITAL Thermal Compensation Activated (Default is Deactivated) 1110 15 DIGITAL Reset Digital Address (9-14) to Default State 1111 16 DIGITAL Idle Condition (S/H Pin Defeated) (Note 3) NOTES: 3. The Idle address is protective in that SB_H input noise cannot disturb the chip if the Idle address is selected; also, the Address inputs are High (selecting Idle state) if the pins are open. 4. Address Numbers 9 - 11 are shaded to indicate test mode conditions and are shown for information only. These addresses are used in original production testing and not required for user applications. However, note that Address No. 15 will force a reset for Address Numbers 9 - 14. 5. Digital Programming: To set the digital addresses, only the proper digital address and a negative pulse >100ns on SB_H is needed. To reset the digital addresses to the default states, Address 15 and a SB_H pulse >100ns is needed. Normally the digital addresses will be set first, and the analog addresses programmed next. The test modes, Address Numbers 9 - 11, will normally only be used during factory testing. An address 15 Reset should normally precede most programming in order to assure that the digital address states begin in their default state. Otherwise, the digital address states will be undefined because there is no power-up-reset. 6. Analog Programming: To program the eight S/H circuits, addresses of 0-5V analog signal on VIN and negative pulses on NullB (10µs) and SB_H (20 µs) pins are needed. The NullB pulse is valid only during the SB_H pulse and should occur during the first half of the SB_H pulse. The S/H amplifier is auto-zeroed for zero offset when both NullB and SB_H are low. The input VIN is captured on the S/H storage capacitor during SB_H low. 7. The Diagnostic mode reads map addresses 1 - 8 via the DIAG output when DIAGINB is low. #11 to 14 #15 #1 to 8 #1 to 8 #1 to 8 #1 to 8 ADDRESS NUMBERS DIGITAL CONTROL S/H INT. TEST #9 or 10 TEST NULL OR S/H (NULL OR S/H) (RESET) SAMPLE NULLB VIN DIAGNOSTIC (SH_B INPUT) INPUT INPUT (DIAGINB INPUT) HIP9022 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |