| поискавой системы для электроныых деталей |
|
UPC1857ACT датащи(PDF) 24 Page - NEC |
|
|
|||||||||||||||||||||||||||||
UPC1857ACT датащи(HTML) 24 Page - NEC |
|
24 / 44 page ![]() 24 µµµµPC1857A 4.4.6 Automatic increment The automatic increment function can be turned ON/OFF by using the data of bit D6 of subaddresses 01H through 04H. This is effective when transmitting data successively (refer to 3.2.2 Successive data transfer). Figure 4-6. Automatic Increment D7 D6 D5 D4 D3 D2 D1 D0 Subaddress 01H-04H Don't care Automatic increment Don't care 0 1 Automatic increment: OFF Automatic increment: ON Automatic increment Caution Subaddress 00H does not have an automatic increment function. It is always set to ON. The automatic increment function automatically increments the subaddress when data is transferred successively. Automatic increment ON : The subaddress is automatically incremented immediately after byte data with D6 = 1 has been transferred. This setting is useful if the data at every subaddress is to be set at once for initialization. The subaddress is always incremented immediately after the data of subaddress: 00H has been transferred. Automatic increment OFF : The subaddress is fixed immediately after byte data with D6 = 0 has been transferred. This setting is useful when the data at the same subaddress is to be successively changed, for example to turn up/down the volume. There is an automatic increment function ON/OFF bit in subaddresses 01H through 04H. Incrementing subaddresses is individually controlled by the automatic increment function ON/OFF bit of each subaddress. For example, if the automatic increment function of subaddress 01H is turned ON, and that of subaddress 02H is turned OFF, the subaddress is automatically incremented from 01H to 02H, and is fixed to 02H. Even if the automatic increment function ON/OFF bit of subaddress 04H is set to ON, the subaddress is not incremented. If the next data is transferred after the data of 04H has been set (acknowledge bit: L), acknowledge enters the NAK status (acknowledge bit: H), and data transfer from the host CPU is stopped. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |