| поискавой системы для электроныых деталей |
|
ILC5140XCS датащи(PDF) 5 Page - Impala Linear Corporation |
|
|
|||||||||||||||||||||||||||||
ILC5140XCS датащи(HTML) 5 Page - Impala Linear Corporation |
|
5 / 6 page ![]() The ILC514X is designed to monitor the terminal voltage of a power source such as a battery and to assert a flag depend- ing on the internally set threshold voltages. Up to four flags can be used to warn of declining stages of a battery’s life. The flags are arranged in order of decreasing threshold val- ues; therefore Flag 1 is asserted at VTH1, Flag 2 is asserted at a voltage VTH2 which is lower than VTH1 and so on. The ILC514C is ideally suited for systems such as PDA’s, note- books and personal electronics where multiple warning and resets are desirable. An example of such a requirement is in a PDA, where Flag 1 is asserted at VTH1 = 2.9V “LOW BAT- TERY WARNING” flag; Flag 2 is asserted at VTH2 = 2.7V “DISABLE CMOS WRITE”; Flag 3 is asserted at VTH3 = 2.5V “DISABLE IrDA PORT” and Flag 4 is asserted at VTH4 = 2.3V “DISABLE SYSTEM EXCEPT CHARGING.” The ILC514X has three output configurations: Open Drain (ILC5140) RESET, Push Pull (ILC5141) RESET and Push Pull (ILC5142) RESET The ILC5140 series will be offered in a variety of voltage thresholds corresponding to industry standard requirements. In addition, customer defined voltage thresholds are avail- able on a special ordering basis. Please consult Impala marketing for conditions surrounding custom thresholds. The ILC5140 samples the input voltage once every 400 ms. This sampling rate was chosen to conserve battery life and at the same time keep a reasonble vigil on the terminal volt- age level. Once the thrshold has been passed, the flag enable function reacts within 30µs. In addition to the 400ms sampling, a sample and hold cir- cuit compares the input voltage to the most recent sample and if there is a DV greater than 20mV the input sampling is turned on continuously until either a flag is asserted or the threshold is regained. If, during the continuous sampling a thrshold is crossed, the flag is enabled. This method inher- ently prevents accidental tripping of the flag during minor input voltage level glitches. Once the threshold is crossed on an increasing voltage level, the flag is disabled 140ms after such a threshold is detected. This is a minimum time since an addtional 400ms may be added if the threshold is not detected at the begin- ning of a regular sampling. The flags are labelled Flag 1, Flag 2, Flag 3, Flag 4. Voltage thrsholds are arranged in order of decreasing volt- age levels, therefore Flag 1 will have a higher threshold than Flag 2 and so on. CMOS Multilevel Voltage Detector Impala Linear Corporation 5 (408) 574-3939 www.impalalinear.com Dec 2000 ILC514x 1.1 Detailed Descripton Threshold Detect to Flag Enable RESET AND RESET Voltage Thresholds Voltage Thrsholds for the Flags Advance |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |