| поискавой системы для электроныых деталей |
|
AT24CS02 датащи(PDF) 13 Page - ATMEL Corporation |
|
|
|||||||||||||||||||||||||||||
AT24CS02 датащи(HTML) 13 Page - ATMEL Corporation |
|
13 / 23 page ![]() 13 AT24CS01/02 [DATASHEET] Atmel-8815D-SEEPROM-AT24CS01-02-Datasheet_082014 Sequential Read: Sequential reads are initiated by either a current address read or a random address read. After the microcontroller receives a data word, it responds with an acknowledge. As long as the EEPROM receives an acknowledge, it will continue to increment the data word address and serially clock out sequential data words. When the memory address limit is reached, the data word address will roll-over and the Sequential Read will continue. The Sequential Read operation is terminated when the microcontroller does not respond with a zero but does generate a following Stop condition. Figure 10-3. Sequential Read Serial Number Read: Reading the serial number is similar to the sequential read sequence but requires use of the device address seen in Figure 8-1 on page 10, a dummy write, and the use of specific word address. Note: The entire 128-bit value must be read from the starting address of the serial number block to guarantee a unique number. Since the address pointer of the device is shared between the regular EEPROM array and the serial number block, a dummy write sequence, as part of a Random Read or Sequential Read protocol, should be performed to ensure the address pointer is set to zero. A Current Address Read of the serial number block is supported but if the previous operation was to the EEPROM array, the address pointer will retain the last location accessed, incremented by one. Reading the serial number from a location other than the first address of the block will not result in a unique serial number. Additionally, the word address must begin with a ‘10’ sequence regardless of the intended address. If a word address other than ‘10’ is used, then the device will output undefined data. Example: If the application desires to read the first byte of the serial number, the word address input would need to be 80h. When the end of the 128-bit serial number is reached (16 bytes of data), the data word address will roll-over back to the beginning of the 128-bit serial number. The Serial Number Read operation is terminated when the microcontroller does not respond with an zero (ACK) and instead issues a Stop condition (see Figure 10-4 on page 14.) R / W A C K A C K A C K A C K N O A C K SDA LINE R E A D S T O P Device Address Data (n + x) Data (n + 2) Data (n + 1) Data (n) |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |