6 / 8 page ![]() Functional Description The following description is for HT7510 only. • Power switch: press switch to turn the power on or off. • When power is on: press the switch, then it will generate a “beep” sound for 0.125 sec. a. Displays all the segments first for 2 sec. b. After a. shows the temperature of the last reading for 2 sec. c. After b. shows L °C (or °F ) for 0.75 sec. d. After c. displays the measurement tem- perature, the °C (or °F) mark will flash at a speed of 1Hz. e. If the temperature < 32 °C (or 90 °F), the display shows L °C (or °F). f. If the temperature ≥ 42 °C (or 108 °F), the display shows H °C (or °F). g. The display always show the higher tem- perature during the measurement. h. If the measured temperature does not change for more than 16 sec, the measure- ment is over and the °C (or °F) mark flash stops. i. When measurement is over, if the tempera- ture > 37.5 °C (or 99.5 °F),the buzzer alarms “Beep-Beep-Beep---Beep-Beep-Beep---” for 4 sec, as follows: if the temperature ≤ 37.5 °C (or 99.5 °F), the buzzer alarms “Beep-Beep-Beep-Beep- ” for 4 sec, as follows: j. If the measurement is over 8 min. 40 sec. the power will automatically turn off k. When the measurement is over and the temperature rises within 8 min. 40 sec, the °C (or °F) mark will flash again (repeat from step 2-d), and starts to count again until 8 min. 40 sec. l. When beep sound is on for 4 sec, the tem- perature is not measured. • When power is off: the standby current ≤ 1µA. • The frequency of the buzzer is 5.3kHz • Bonding option: °C or °F. • Measurement to 0.1 degree in either °C or °F. • Sensor use 503ET. • Reference resistor value (sensor in 37.0 °C) • When battery voltage is low, the battery mark “ ∇” flashes at a speed of 1 Hz and the meas- urement may not be accurate. The low voltage detect: 2.4V ± 0.05V. • During the process of mass production, in or- der to adjust the reference resistance (RF), let test 2 be floating, the measured temperature will be the actual temperature of the meas- ured environment. It can be up or down, not always the higher one. Selection table for clinical thermometer Part No. Voice Language HT84018-0D English HT7510 6 10th Feb ’99 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |