| поискавой системы для электроныых деталей |
|
DP2-21 датащи(PDF) 10 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
DP2-21 датащи(HTML) 10 Page - List of Unclassifed Manufacturers |
|
10 / 15 page ![]() kPa MPa kgf/cm2 bar psi mmHg inHg atm (Torr) 1 kPa 1 1 10 3 1.01972 10 2 1 10 2 1.45038 10 1 7.50062 0.2953 9.86923 10 3 1 MPa 1 103 1 1.01972 10 1 10 1.45038 102 7.50062 103 0.2953 103 9.86923 1 kgf/cm2 9.80665 10 9.80665 10 2 1 9.80665 10 1 1.42234 10 7.35559 102 2.8959 10 9.67841 10 1 1 bar 1 102 1 10 1 1.01972 1 1.45038 10 7.50062 102 2.953 10 9.86923 10 1 1 psi 6.89473 6.89473 10 3 7.03065 10 2 6.89473 10 2 1 5.17147 10 2.036 6.80457 10 2 1 mmHg 1.33322 10 1 1.33322 10 4 1.35951 10 3 1.33322 10 3 1.93368 10 2 1 3.9370 10 2 1.31579 10 3 (1 Torr) 1 inHg 3.3864 3.3864 10 3 3.4531 10 2 3.3864 10 2 0.4912 2.5400 10 1 3.342 10 2 1 atm 1.01325 102 1.01325 10 1 1.03323 1.01325 1.46960 10 7.60000 102 2.9921 10 1 PRECAUTIONS FOR PROPER USE DP2 801 Conversion procedure Conversion table for pressure units Conversion of pressure units • In the DP2 series, the conversion to different units is automatically done on changing the setting of the pressure unit. However, this conversion can also be obtained by multiplying the values by the coefficients given in the table on the right. • For example, if 2 kPa is to be expressed in kgf/cm2, since 1 kPa 1.01972 10 2 kgf/cm2, 2 kPa becomes 2 1.01972 10 2 c 0.020 kgf/cm2. Setting of key-protect Key-protect function • Key-protect is a function which prevents any unintentional change in the conditions which have been entered in each setting mode by making the sensor not to respond to the key operations. • In the sensing mode, press key continuously for about 3 sec. and release it immediately when is displayed. • Key-protect is set and the sensor returns to the sensing mode. MODE Others • Use within the rated pressure range. • Do not apply pressure exceeding the pressure with- standability value. The diaphragm will get damaged and correct operation shall not be maintained. • Do not use during the initial transient time (0.5 sec.) after the power supply is switched on. • Avoid use of standard type, flat type and light weight type of sensors in places where steam and dust is excessive. • Take care that the sensor does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. • Do not insert wires, etc., into the pressure port. The diaphragm will get damaged and correct operation shall not be maintained. • Do not operate the keys with pointed or sharp objects. DP2-20 –101.3kPa OUT2 OUT1 MODE 0-ADJ All models Release of key-protect • In the sensing mode, press key continuously for about 3 sec. and release it immediately when is displayed. • Key-protect is released and the sensor returns to the sensing mode. MODE DP2-20 –101.3kPa OUT2 OUT1 MODE 0-ADJ |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |