35 / 43 page ![]() Ericsson Internal PRODUCT SPECIFICATION 3 (6) Prepared (also subject responsible if other) No. ESHUHAN 3/1301-BMR 655 Uen Approved Checked Date Rev Reference SEC/D (Betty Wu) EZHEWNG 2009-2-13 C Operating information continued Parallel Operation Two converters may be paralleled for redundancy if the total power is equal or less than PO max. It is not recommended to parallel the converters without using external current sharing circuits. See Design Note 006 for detailed information. Remote Sense The DC/DC converters have remote sense that can be used to compensate for voltage drops between the output and the point of load. The sense traces should be located close to the PCB ground layer to reduce noise susceptibility. The remote sense circuitry will compensate for up to 10% voltage drop between output pins and the point of load. If the remote sense is not needed +Sense should be connected to +Out and -Sense should be connected to -Out. Over Temperature Protection (OTP) The converters are protected from thermal overload by an internal over temperature shutdown circuit. When Tp1 as defined in thermal consideration section exceeds 135°C the converter will shut down. The DC/DC converter will make continuous attempts to start up (non- latching mode) and resume normal operation automatically when the temperature has dropped >10°C below the temperature threshold. The converters with latching option will shut down the module when Tp1 exceeds 135°C and remain shut down until the module restarts by switching on/off the input voltage or Remote control. Over Voltage Protection (OVP) The converters have output over voltage protection that will shut down the converter in over voltage conditions. The converter will make continuous attempts to start up (non- latching mode) and resume normal operation automatically after removal of the over voltage condition. The converters with latching option will shut down the module in over voltage condition and remain shut down until the converter restarts by switching on/off the input voltage or Remote control. Over Current Protection (OCP) The converters include current limiting circuitry for protection at continuous overload. The output voltage will decrease towards 30% of nominal output voltage for output currents in excess of max output current (max IO). When reaching 30% of nominal output voltage the converter will go into hic-up mode. The converter will resume normal operation after removal of the overload. The load distribution should be designed for the maximum output short circuit current specified. The converters with latching option will shut down the module when reaching 30% of nominal output voltage and remain shut down until the converter restarts by switching on/off the input voltage or Remote control. Pre-bias Start-up The converter has a Pre-bias start up functionality. The converter will sink current in a controlled way during start up if a pre-bias source is present at the output terminals. E PKB4000C series Direct Converters Input 36-75 V, Output up to 60 A / 144 W EN/LZT 146 377 R4 D September 2013 © Ericsson AB Technical Specification 35 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |