| поискавой системы для электроныых деталей |
|
ACT3780 датащи(PDF) 11 Page - Active-Semi, Inc |
|
|
|||||||||||||||||||||||||||||
ACT3780 датащи(HTML) 11 Page - Active-Semi, Inc |
|
11 / 20 page ![]() ACT3780 Rev 8, 09-Jul-13 Innovative PowerTM - 11 - www.active-semi.com Copyright © 2013 Active-Semi, Inc. Active-Semi Proprietary―For Authorized Recipients and Customers ActivePath TM is a trademark of Active-Semi. kHOT(@TC) = VTHH/(RNOM × (ITH + (VCHG_IN - VTHH)/R)) kHOT(@TC) = 0.5V/(6.8kΩ × (100µA + (5V - 0.5V)/82kΩ)) = 0.4748 Reviewing the characteristic curves, the upper threshold is found to move to 45°C, a change of about 14°C. Adding the parallel resistance has allowed us to achieve our desired lower threshold of 0°C with an operating temperature range of 0°C to 45°C, vs. our design target of 0°C to 40°C. Thermal Regulation and Protection The ACT3780 features an internal thermal regulation loop that reduces the charging current as necessary to ensure that the die temperature does not rise beyond the thermal regulation threshold of 110°C. This feature protects the ACT3780 against excessive junction temperature and makes the device more accommodating to aggressive thermal designs. Note, however, that attention to good thermal designs is required to achieve the fastest possible charge time by maximizing charge current. In order to account for the extended total charge time resulting from operation in thermal regulation mode, the charge timeout periods are extended proportionally to the reduction in charge current. The conditions that cause the ACT3780 to reduce charge current in accordance to the internal thermal regulation loop can be approximated by calculating the power dissipated in the part. The ACT3780 also features thermal shutdown for further protection. When the device temperature exceeds 160°C, the device will automatically turn off to prevent the IC from damage. After the die temperature decreases below 135°C, the IC will automatically restart. Charging Safety Timers The ACT3780 features a programmable safety charging timer by setting an external resistor from BTR pin to G (RBTR). The time out period is calculated as shown in Figure 2. The maximum RBTR should not be larger than 68kΩ. If the timeout period expires without change termination, the ACT3780 will jump to EOC state. If the ACT3780 detects that the charger remains in precondition for longer than the precondition time out period (which determined as TNORMAL/3), the ACT3780 turns off the charger and generates a FAULT to ensure prevent charging a bad cell. Figure 3: Fix VTHL Configuration Figure 4: Fix VTHH Configuration Figure 2: RBTR (kΩ) 30 35 40 45 50 55 60 65 70 TNORMAL vs. RBTR 190 160 130 100 70 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |