| поискавой системы для электроныых деталей |
|
DPM2000 датащи(PDF) 1 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
DPM2000 датащи(HTML) 1 Page - List of Unclassifed Manufacturers |
|
1 / 2 page ![]() DIMENSIONS All dimensions in mm (inches) Required F.S.R. Ra Rb 2V Note 910k 100k 20V Note 1M 10k 200V Note 1M 1k 2kV Note 1M 100R 200 A link 1k 2mA link 100R 20mA link 10R 200mA link 1R µ 15mm (0.6“) Digit Height Programmable Decimal Points Auto-zero Auto-polarity 200mV d.c. Full Scale Reading (F.S.R.) Single Rail Version DPM 2000 3 ½ Digit LCD Module The DPM 2000 uses advanced components and construction techniques to provide an unrivalled combination of high performance, elegant appearance and low cost. The module uses a bandgap reference for extra temperature stability. For single rail operation, the DPM 2000S features a built-in negative rail generator, enabling the meter to measure a signal referenced to its own power supply 0V. Specification Min. Typ. Max. Unit Accuracy (overall error) * 0.05 0.1 % (±1 count) Linearity ±1 count Sample rate 3 samples/sec Operating temperature range 0 50 °C Temperature s 30 ppm/°C Supply DPM 2000 7.5 9 14 (V+ to V-) DPM 2000S 3.5 5 6.5 V Supply current DPM 2000 150 DPM 2000S 500 A Input leakage current (Vin = 0V) 1 10 pA * To ensure maximum accuracy, re-calibrate periodically. tability voltage µ Stock Number Standard Meter DPM 2000 Single Rail Version DPM 2000S ON BOARD SOLDER LINKS SCALING RESISTORS SCALING NOTE 67.5 (2.66) 60.0 (2.36) 53.0 (2.09) 62.5 (2.46) Ø2.50 (0.10) cd e fg Display in TEST mode a. 1.00 (0.04) b. 9.00 (0.35) c. 1.25 (0.05) d. 5.50 (0.22) e. 4.00 (0.16) f. 0.50 (0.02) g. 2.54 (0.10) LMP 8 13 12 H5 9 6 14 11 4 2 7 5 1 3 10 Rb Ra Two resistors Ra and Rb may be fitted in order to alter the full scale reading (F.S.R) of the meter - see table. The meter will need re-calibration. Ensure that link 10 is open if fitting Ra. SAFETY To comply with the Low Voltage Directive (LVD 93/68/EEC), input voltages to the module’s pins must not exceed 60Vdc. If voltages to the measuring inputs do exceed 60Vdc, then fit scaling resistors externally to the module. The user must ensure that the incorporation of the DPM into the user’s equipment conforms to the relevant sections of BS EN 61010 (Safety Requirements for Electrical Equipment for Measuring, Control and Laboratory Use). 72.0 (2.83) ab |
Аналогичный номер детали - DPM2000 |
|
Аналогичное описание - DPM2000 |
|
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |