| поискавой системы для электроныых деталей |
|
ZSC31015 датащи(PDF) 21 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
ZSC31015 датащи(HTML) 21 Page - List of Unclassifed Manufacturers |
|
21 / 53 page ![]() ZSC31015 RBicdLite™ Analog Output Sensor Signal Conditioner w/ Diagnostic Features Data Sheet October 28, 2012 © 2012 Zentrum Mikroelektronik Dresden AG — Rev. 2.00 All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The information furnished in this publication is subject to changes without notice. 21 of 52 2.5. Clock Generator / Power-On Reset (CLKPOR) If the power supply exceeds 2.5V (maximum), the reset signal de-asserts and the clock generator starts working at a frequency of approximately 512kHz (±20%). The exact value only influences the conversion cycle time and communication to the outside world but not the accuracy of signal processing. In addition, to minimize the oscillator error as the VDD voltage changes, an on-chip regulator is used to supply the oscillator block. 2.5.1. Trimming the Oscillator Settings for the Osc_Trim bits in EEPROM fine-tune the oscillator frequency. See Table 3.5 for bit locations and Table 2.2 for possible settings. The default value is 0HEX to ensure communication on start-up. Important: Optimal oscillator trimming is determined during wafer-level testing and final package testing, and this part-specific factory value, which can be copied to Osc_Trim, is stored in bits in the CUST_ID1 and CUST_ID2 EEPROM bits for applications requiring optimal response time. In this case, see section 5 for important notes and instructions for copying these optimal values to the Osc_Trim bits before calibration. It is strongly recommended that only the default value or the factory trim value be used because ZACwire TM communication is not guaranteed at different oscillator frequencies. Table 2.2 Oscillator Trimming Osc_Trim Bits Delta Frequency (kHz) 100 +385 101 +235 110 +140 111 +65 000 Nominal 001 -40 010 -76 011 -110 Example: Programming 011B the trimmed frequency = nominal value - 110 kHz. 2.6. Diagnostic Features The RBicdLite TM offers a full suite of diagnostic features to ensure robust system operation in the most “mission- critical” applications. If the part is programmed in Analog Output Mode, then diagnostic states are indicated by an output below 2.5% of VDD or above 97.5% of VDD. If the part is programmed in Digital Output Mode, then diagnostic states will be indicated by a transmission with a generated parity error. Table 2.3 gives a summary of the diagnostic features, which are explained in detail in the following sections. EEPROM settings that control diagnostic functions are given in section 3.5. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |