10 / 31 page ![]() DS2407 012099 10/31 If the CRC read by the bus master is incorrect, a Reset Pulse must be issued and the entire sequence must be repeated. If the CRC received by the bus master is cor- rect, a programming pulse (12 volts on the 1–Wire bus for 480 µs) is issued by the bus master. Prior to program- ming, the entire unprogrammed EPROM memory field will appear as logical 1s. For each bit in the data byte provided by the bus master that is set to a logical 0, the corresponding bit in the selected byte of the EPROM memory is programmed to a logical 0 after the program- ming pulse has been applied. After the 480 µs programming pulse is applied and the data line returns to the idle level (5 volts), the bus master issues eight read time slots to verify that the appropriate bits have been programmed. The DS2407 responds with the data from the selected EPROM address sent least significant bit first. This byte contains the bitwise logical AND of all data ever written to this address. If the EPROM byte contains 1s in bit positions where the byte issued by the master contained 0s, a Reset Pulse should be issued and the current byte address should be programmed again. If the DS2407 EPROM byte con- tains 0s in the same bit positions as the data byte, the programming was successful and the DS2407 will auto- matically increment its address counter to select the next byte in the EPROM memory field. The new two– byte address will also be loaded into the 16–bit CRC generator as a starting value. The bus master will issue the next byte of data using eight write time slots. As the DS2407 receives this byte of data into the scratchpad, it also shifts the data into the CRC genera- tor that has been preloaded with the current address and the result is a 16–bit CRC of the new data byte and the new address. After supplying the data byte, the bus master will read this 16–bit CRC from the DS2407 with sixteen read time slots to confirm that the address incremented properly and the data byte was received correctly. If the CRC is incorrect, a Reset Pulse must be issued and the write sequence must be restarted. If the CRC is correct, the bus master will issue a programming pulse and the selected byte in memory will be pro- grammed. Note that the initial pass through the write flow chart will generate an 16–bit CRC value that is the result of shift- ing the command byte into the CRC generator, followed by the two address bytes, and finally the data byte. Sub- sequent passes through the write flow chart due to the DS2407 automatically incrementing its address counter will generate a 16–bit CRC that is the result of loading (not shifting) the new (incremented) address into the CRC generator and then shifting in the new data byte. For both of these cases, the decision to continue (to apply a program pulse to the DS2407) is made entirely by the bus master, since the DS2407 will not be able to determine if the 16–bit CRC calculated by the bus mas- ter agrees with the 16–bit CRC calculated by the DS2407. If an incorrect CRC is ignored and a program pulse is applied by the bus master, incorrect program- ming could occur within the DS2407. Also note that the DS2407 will always increment its internal address counter after the receipt of the eight read time slots used to confirm the programming of the selected EPROM byte. The decision to continue is again made entirely by the bus master. Therefore if the EPROM data byte does not match the supplied data byte but the master contin- ues with the write command, incorrect programming could occur within the DS2407. The write command sequence can be ended at any point by issuing a Reset Pulse. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |