| поискавой системы для электроныых деталей |
|
LBA110STR датащи(PDF) 3 Page - Clare, Inc. |
|
|
|||||||||||||||||||||||||||||
LBA110STR датащи(HTML) 3 Page - Clare, Inc. |
|
3 / 8 page ![]() LBA110 www.clare.com Rev. 5 PERFORMANCE DATA* The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. 3 LBA110 Typical LED Forward Voltage Drop (N=50 Ambient Temperature = 25 °C; IF = 5mADC) 35 30 25 20 15 10 5 0 1.17 1.19 1.21 1.23 1.25 LED Forward Voltage Drop (V) LBA110 - FormA Typical On-Resistance Distribution (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC, IF=5mADC) 35 30 25 20 15 10 5 0 19.5 21.5 23.5 25.5 20.5 22.5 24.5 On-Resistance ( Ω) LBA110 - FormB Typical On-Resistance Distribution (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC, IF=5mADC) 25 20 15 10 5 0 25.5 27.5 29.5 31.5 26.5 28.5 30.5 On-Resistance ( Ω) LBA110 - FormA Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25 °C) 35 30 25 20 15 10 5 0 400 440 480 520 420 460 500 Blocking Voltage (V) LBA110 - FormB Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25 °C) 30 25 20 15 10 5 0 365 385 405 425 375 395 415 Blocking Voltage (V) LBA110 - FormA Typical IF for Switch Dropout (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC) 25 20 15 10 5 0 0.65 1.17 1.69 0.39 0.91 1.43 1.95 LED Current (mA) LBA110 - FormB Typical IF for Switch Dropout (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC) 25 20 15 10 5 0 0.9 1.3 1.7 0.7 1.1 1.5 1.9 LED Current (mA) LBA110 - FormA Typical IF for Switch Operation (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC) 0.65 1.17 1.69 0.91 1.43 1.95 LED Current (mA) 25 20 15 10 5 0 LBA110 - FormB Typical IF for Switch Operation (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC) 25 20 15 10 5 0 0.7 1.1 1.5 1.9 0.9 1.3 1.7 LED Current (mA) LBA110 - FormA Typical Turn-On Time (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC; IF = 5mADC) 0.45 1.05 1.65 0.75 1.35 Turn-On (ms) 25 20 15 10 5 0 LBA110 - FormB Typical Turn-On Time (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC; IF = 5mADC) 0.25 0.45 0.65 0.35 0.55 0.75 Turn-On (ms) 25 20 15 10 5 0 LBA110 - FormA Typical Turn-Off Time (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC; IF = 5mADC) 0.12 0.28 0.44 0.60 0.52 0.36 0.20 Turn-Off (ms) 25 20 15 10 5 0 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |