24 / 33 page ![]() www.clare.com 24 CPC5604 XXX +0 -2 -4 -6 -8 -10 -12 -14 -16 -18 -20 -22 -24 -26 -28 -30 -32 -34 -36 -38 -40 THL (dBm) 500 1K 1.5K 2K Frequency (Hz) 2.5K 3K 3.5K 4K Trans-Hybrid Loss As shown in Figure 6A, the Audio Precision, AP1 injects a signal into the Tx inputs and measures the energy at Rx with Tip and Ring terminated by a 600 Ω nominal Audio Precision Generator RX- RX+ TIP RING 500 10H 500 10H 500uf 600 48V + - 40mA Loop Current Audio Precision System One Analyzer 100K V IN1 IN2 AP1 50 V -3dBm/30Hz-4kHz TX+ TX- LITELINK TM DAA Circuit THL = 20 log (V /V ) RX TX RX TX OH Figure 6A Trans-Hybrid Loss (THL) Test Setup Figure 6B Trans-Hybrid Loss at Rx± with -3dBm Signal on Tx± Matched to 600 Ω Impedance on T/R impedance. The Tx input frequency is swept from 30Hz- 4000Hz and the amplitude of the signal is measured on the Rx inputs and graphed in Figure 6B. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|