21 / 37 page ![]() RENESAS TECHNICAL UPDATE TN-RL*-A024A/E Date: Apr. 9, 2014 Page 21 of 37 7. 14. 5 Caution for Using Timer KB Simultaneous Operation Function As respects of INTP2m and comparator, Caution for Using Timer KB Simultaneous Operation Function is added. Incorrect: No applicable item Correct: 14. 5 Caution for Using Timer KB Simultaneous Operation Function In addition to their use as an external interrupt input, the INTP2m pin output and the comparator output signal can be used as a trigger for functions that operate simultaneously with timer KB, such as the forced output stop function and timer restart function. The settings in peripheral function switch register 0 (PFSEL0) and the edge selection registers must be specified according to the function used. The width of the active signal required until each function starts operating differs. When using INTP2m or the comparator output signal, refer to Tables 14-4 to 14-6 to specify the necessary register settings, and configure external circuits so that the required active signal width is assured. Table 14-4. Relationship of INTP2m function, register settings, and active signal width Function Peripheral enable register setting Edge setting registers Necessary active signal width to operate each function Interrupt Forced output stop Timer restart External interrupt (STOP release is enabled) TMRSTENm = 0 EGPn, EGNn To 1 s - - Forced output stop Note 1 TMRSTENm = 1 CEGPp, CEGNp Note 2 55 to 215 ns Note 3 + 2 to 3 clocks Note 4 55 to 215 ns Note 3, 5 - Timer restart TMRSTENm = 1 CEGPp, CEGNp 55 to 215 ns Note 3 + 2 to 3 clocks Note 4 - 55 to 215 ns Note 3 + 2 to 3 clocks Note 4, 6 Figure 14-18. Generation Timing of Forced Output Stop Signal and Timer Restart Request Signal by INTP2m INTP2m pin Timer restart request signal, Interrupt request signal Forced output stop request signal Note 1 Internal wait time (55 to 215 ns ) Note 3, 5 Edge comfirming time (2 to 3 clocks ) Note 4, 6 Notes 1. Only INTP20 can be used as a trigger for forced output stop function 2. 2. The active level of INTP20 (used for forced output stop function 2) is high. Edge selection is only applied to detection of an interrupt signal. 3. 5 to 15 ns when noise filtering on INTP20 is disabled (PNFEN = 1) 4. For fCLK or fPLL (when PLLON = 1) 5. An additional output delay time (10 to 40 ns) is required from when forced output stop function 2 starts operating to when the level of the timer KB output changes. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |