| поискавой системы для электроныых деталей |
|
AS8501 датащи(PDF) 26 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS8501 датащи(HTML) 26 Page - ams AG |
|
26 / 41 page ![]() AS8501 - Data Sheet austriamicrosystems Revision 1.1, 04-April-06 www.austriamicrosystems.com Page 25 of 40 7.5.8 THR alarm (Wake-up) threshold register ( 17 bits ) Nr. MR16 MR15 MR14 MR13 MR12 MR11 … MR1 MR0 NOTE 0 A/B s Msb lsb default 0 0 1 0 0 0 1) Notes: 1) _ All measurements are performed in channel A therefore MR16 must be set to zero. When channel B is selected no interrupt will be generated. - The signed value is used. For positive THR values the ASSP will initiate an interrupt whenever the measured value is bigger than the THR value. For negtive THR values the interrupt will be generated for a negative result with an absolute value bigger than the absolute value of the THR register. 7.5.9 MSR measurement result register ( 18 bits ) Nr. MR17 MR16 MR15 MR14 MR13 MR12 MR11 … MR1 MR0 NOTE Overflow/un derflow A/B S msb lsb 1) Notes: 1) - Result word length is 16 bits because of calibration accuracy and to maintain all possible resolutions ( different setting ). - A/B bit signifies which measurement was performed: the one defined in CRA or CRB: MR16=0 -> A MR16=1 -> B - Overflow/underflow bit is set whenever the result after multiplication by calibration constant is bigger than 32767 or smaller than –32767. In Wake-up or Alarm mode the overflow/underflow always sets INTN signal to LO. 8 Digital interface description The digital interface of the AS8501 consists of two input pins (CLK and SCLK) and two I/O pins (INTN and SDAT). The SCLK and SDAT pins are used as universal serial data interface (SDI). SDI operates only if external clock signal (CLK) is running. 8.1 CLK In all operating modes except the Wake-up mode this pin must be connected to 8 MHz clock signal. In the Wake-up mode (MWU) the CLK pin must be connected to logic HI or float. 8.2 INTN The INTN pin is used to signal various conditions to the microcontroller, depending on the operating mode. application modes of the INTN pin Mode Signal Direction Purpose Note 0 Load clock (internal) Output Indicates progress of the Zener-Zap load process 1) 1, 2,7 SDI clock disable Output Signals new result and suggests when to disable SCLK in high-precision measurement phase 2) 3 idle / wake-up not Output Signals the wake-up condition 4 idle / alarm not Output Signals the alarm condition 5 PW1 Input Shows the programming pulse width 6,8,9 Logic ‘0’ Output No purpose 10 t12 Output Test mode 10 t18 Output Test mode Notes: 1) 188 clock pulses are generated from the internal oscillator source during the loading time. 2) In measurement modes (MMS and MMD) the INTN pin is used to synchronize the SDI bus operations (See Fig. 9). The trailing edge of INTN signals the start of a new measurement. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |